EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The Design and Validation of an Open-Palm Data Glove for Precision Finger and Wrist Tracking

Olivia Hosie iD, Mats Isaksson iD, John McCormick, Oren Tirosh iD, Chrys Hensman

Sensors · 2025

DOI: 10.3390/s25020367 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Olivia Hosie und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Engineering, Swinburne University of Technology, Hawthorn, VIC 3122, Australia. Hauptthemen laut MEDLINE: Fingers, Wrist, Hand. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wearable motion capture gloves enable the precise analysis of hand and finger movements for a variety of uses, including robotic surgery, rehabilitation, and most commonly, virtual augmentation. However, many motion capture gloves restrict natural hand movement with a closed-palm design, including fabric over the palm and fingers. In order to alleviate slippage, improve comfort, reduce sizing issues, and eliminate movement restrictions, this paper presents a new low-cost data glove with an innovative open-palm and finger-free design. The new design improves usability and overall functionality by addressing the limitations of traditional closed-palm designs. It is especially beneficial in capturing movements in fields such as physical therapy and robotic surgery. The new glove incorporates resistive flex sensors (RFSs) at each finger and an inertial measurement unit (IMU) at the wrist joint to measure wrist flexion, extension, ulnar and radial deviation, and rotation. Initially the sensors were tested individually for drift, synchronisation delays, and linearity. The results show a drift of 6.60°/h in the IMU and no drift in the RFSs. There was a 0.06 s delay in the data captured by the IMU compared to the RFSs. The glove’s performance was tested with a collaborate robot testing setup. In static conditions, it was found that the IMU had a worst case error across three trials of 7.01° and a mean absolute error (MAE) averaged over three trials of 4.85°, while RFSs had a worst case error of 3.77° and a MAE of 1.25° averaged over all five RFSs used. There was no clear correlation between measurement error and speed. Overall, the new glove design proved to accurately measure joint angles.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FingersWristHandHumansWearable Electronic DevicesEquipment DesignMovementRobotics

Stichwörter der Autor:innen

data gloveinertial measurement unit (IMU)open-palm designresistive flex sensor (RFS)wearable technology

Autor:innen und Institutionen

  • School of Engineering, Swinburne University of Technology, Hawthorn, VIC 3122, Australia.
  • Centre for Transformative Media Technologies, Swinburne University of Technology, Hawthorn, VIC 3122, Australia.
  • School of Health and Biomedical Sciences, Royal Melbourne Institute of Technology, Melbourne, VIC 3000, Australia.
  • School of Health Science, Swinburne University of Technology, Hawthorn, VIC 3122, Australia.
  • College of Rehabilitation Sciences, Shanghai University of Medicine and Health Sciences, Shanghai 200237, China.
  • Division of Robotics, Swinburne University of Technology, Hawthorn, VIC 3122, Australia.

ORCID-Profile: Olivia Hosie, Mats Isaksson, Oren Tirosh

Zitieren

APA

Hosie, O., Isaksson, M., McCormick, J., Tirosh, O., & Hensman, C. (2025). The Design and Validation of an Open-Palm Data Glove for Precision Finger and Wrist Tracking. Sensors. https://doi.org/10.3390/s25020367

Vancouver

Hosie O, Isaksson M, McCormick J, Tirosh O, Hensman C. The Design and Validation of an Open-Palm Data Glove for Precision Finger and Wrist Tracking. Sensors. 2025. doi:10.3390/s25020367

BibTeX
@article{Hosie2025,
  author = {Hosie, Olivia and Isaksson, Mats and McCormick, John and Tirosh, Oren and Hensman, Chrys},
  title = {The Design and Validation of an Open-Palm Data Glove for Precision Finger and Wrist Tracking},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25020367}
}
Kostenlos starten →