Heat Stroke Warning System Prototype for Athletes: A Pilot Study
Sensors · 2025
DOI: 10.3390/s25020294 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Kanchana Silawarawet und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Computer Engineering, Faculty of Engineering, Thammasat School of Engineering, Thammasat University, Pathumthani 12120, …. Hauptthemen laut MEDLINE: Heat Stroke, Athletes. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Department of Electrical and Computer Engineering, Thammasat School of Engineering, Faculty of Engineering, Thammasat University.
Themen: Schlaganfall
Abstract (Originalsprache)
This research has developed a heat stroke warning system prototype for athletes utilizing the following sensors: DHT22, GY-906-BAA MLX90614, MAX30102. The device calculates the heat stroke risk and notifies users. The data is recorded, stored, displayed on a free-access website which graphs body temperature, ambient temperature, humidity, heart rate and heat stroke risk, and provides notifications for athletes engaged in outdoor activities. The researchers recorded sensors data (n = 1) for two sessions (12 min/session) in a closed room, at the sixth-minute marker, with an air conditioner activated to observe the changes observed by the sensors. For accuracy, the researchers employed Criterion-Related Validity, comparing sensor against standard equipment measurement. For reliability, we utilized Test-Retest Reliability, comparing sensor data from the first and second measurements. Accuracy and reliability were evaluated using the Pearson Correlation Coefficient, with significance set at p < 0.01. The DHT22 sensor demonstrates very high accuracy (r = 0.923) in ambient temperature and (r = 0.774) humidity measurements. It showed no significant reliability (r = 0.489) in temperature and (r = 0.185) humidity measurements. The GY-906-BAA MLX90614 sensor exhibited very high accuracy (r = 0.923) and reliability (r = 0.866) in body temperature measurements. The MAX30102 sensor lacked significant accuracy (r = 0.179) and reliability (r = 0.171) in heart rate measurements. The development of accuracy and reliability of sensors are important for preventing heat stroke in future applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrical and Computer Engineering, Faculty of Engineering, Thammasat School of Engineering, Thammasat University, Pathumthani 12120, Thailand.
- Department of Sports Science and Sports Development, Faculty of Allied Health Sciences, Thammasat University, Pathumthani 12120, Thailand.
ORCID-Profile: Kanchana Silawarawet, Phattarakorn Kaewchukul, Sairag Saadprai
Förderung
- Department of Electrical and Computer Engineering, Thammasat School of Engineering, Faculty of Engineering, Thammasat University
Zitieren
APA
Silawarawet, K., Kaewchukul, P., & Saadprai, S. (2025). Heat Stroke Warning System Prototype for Athletes: A Pilot Study. Sensors. https://doi.org/10.3390/s25020294
Vancouver
Silawarawet K, Kaewchukul P, Saadprai S. Heat Stroke Warning System Prototype for Athletes: A Pilot Study. Sensors. 2025. doi:10.3390/s25020294
BibTeX
@article{Silawarawet2025,
author = {Silawarawet, Kanchana and Kaewchukul, Phattarakorn and Saadprai, Sairag},
title = {Heat Stroke Warning System Prototype for Athletes: A Pilot Study},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25020294}
}
EUVIMED