EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Performance Improvement with Reduced Number of Channels in Motor Imagery BCI System

Ali Özkahraman iD, Tamer Ölmez, Zümray Dokur iD

Sensors · 2024

DOI: 10.3390/s25010120 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Ali Özkahraman und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronics and Communication Engineering, Istanbul Technical University, 34467 Istanbul, Istanbul, Turkey. Hauptthemen laut MEDLINE: Brain-Computer Interfaces, Electroencephalography, Imagination. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Classifying Motor Imaging (MI) Electroencephalogram (EEG) signals is of vital importance for Brain–Computer Interface (BCI) systems, but challenges remain. A key challenge is to reduce the number of channels to improve flexibility, portability, and computational efficiency, especially in multi-class scenarios where more channels are needed for accurate classification. This study demonstrates that combining Electrooculogram (EOG) channels with a reduced set of EEG channels is more effective than relying on a large number of EEG channels alone. EOG channels provide useful information for MI signal classification, countering the notion that they only introduce eye-related noise. The study uses advanced deep learning techniques, including multiple 1D convolution blocks and depthwise-separable convolutions, to optimize classification accuracy. The findings in this study are tested on two datasets: dataset 1, the BCI Competition IV Dataset IIa (4-class MI), and dataset 2, the Weibo dataset (7-class MI). The performance for dataset 1, utilizing 3 EEG and 3 EOG channels (6 channels total), is of 83% accuracy, while dataset 2, with 3 EEG and 2 EOG channels (5 channels total), achieves an accuracy of 61%, demonstrating the effectiveness of the proposed channel reduction method and deep learning model.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Brain-Computer InterfacesElectroencephalographyImaginationHumansElectrooculographySignal Processing, Computer-AssistedDeep LearningAlgorithmsBrain

Stichwörter der Autor:innen

eeg channel reductionelectroencephalography classificationeog noisemotor imagery bci system

Autor:innen und Institutionen

  • Department of Electronics and Communication Engineering, Istanbul Technical University, 34467 Istanbul, Istanbul, Turkey.
  • Department of Electrical and Electronics Engineering, Iskenderun Technical University, 31200 Iskenderun, Hatay, Turkey.

ORCID-Profile: Ali Özkahraman, Zümray Dokur

Zitieren

APA

Özkahraman, A., Ölmez, T., & Dokur, Z. (2024). Performance Improvement with Reduced Number of Channels in Motor Imagery BCI System. Sensors. https://doi.org/10.3390/s25010120

Vancouver

Özkahraman A, Ölmez T, Dokur Z. Performance Improvement with Reduced Number of Channels in Motor Imagery BCI System. Sensors. 2024. doi:10.3390/s25010120

BibTeX
@article{zkahraman2024,
  author = {Özkahraman, Ali and Ölmez, Tamer and Dokur, Zümray},
  title = {Performance Improvement with Reduced Number of Channels in Motor Imagery BCI System},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s25010120}
}
Kostenlos starten →