Key Parameters for Performance and Resilience Modeling of 3D Time-of-Flight Cameras Under Consideration of Signal-to-Noise Ratio and Phase Noise Wiggling
Sensors · 27.12.2024 · 25 (1) · 109
DOI: 10.3390/s25010109 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 27.12.2024. Verfasst von Niklas Alexander Köhler und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Health, University of Applied Sciences Mittelhessen, 35390 Giessen, Germany. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: German Federal Ministry of Education and Research (BMBF).
Abstract (Originalsprache)
Because of their resilience, Time-of-Flight (ToF) cameras are now essential components in scientific and industrial settings. This paper outlines the essential factors for modeling 3D ToF cameras, with specific emphasis on analyzing the phenomenon known as “wiggling”. Through our investigation, we demonstrate that wiggling not only causes systematic errors in distance measurements, but also introduces periodic fluctuations in statistical measurement uncertainty, which compounds the dependence on the signal-to-noise ratio (SNR). Armed with this knowledge, we developed a new 3D camera model, which we then made computationally tractable. To illustrate and evaluate the model, we compared measurement data with simulated data of the same scene. This allowed us to individually demonstrate various effects on the signal-to-noise ratio, reflectivity, and distance.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Health, University of Applied Sciences Mittelhessen, 35390 Giessen, Germany.
- Institute of Safety and Security Research (ISF), Hochschule Bonn-Rhein-Sieg, 53757 Sankt Augustin, Germany.
- Department of Electrical Engineering and Information Technology, University of Applied Sciences Mittelhessen, 35390 Giessen, Germany.
ORCID-Profile: Niklas Alexander Köhler, Marcel Geis, Claudius Nöh, Alexandra Mielke, Volker Groß, Robert Lange, Keywan Sohrabi, Jochen Frey
Förderung
- German Federal Ministry of Education and Research (BMBF)
Zitieren
APA
Köhler, N. A., Geis, M., Nöh, C., Mielke, A., Groß, V., Lange, R., Sohrabi, K., & Frey, J. (2024). Key Parameters for Performance and Resilience Modeling of 3D Time-of-Flight Cameras Under Consideration of Signal-to-Noise Ratio and Phase Noise Wiggling. Sensors, 25(1), 109. https://doi.org/10.3390/s25010109
Vancouver
Köhler NA, Geis M, Nöh C, Mielke A, Groß V, Lange R, et al. Key Parameters for Performance and Resilience Modeling of 3D Time-of-Flight Cameras Under Consideration of Signal-to-Noise Ratio and Phase Noise Wiggling. Sensors. 2024;25(1):109. doi:10.3390/s25010109
BibTeX
@article{Khler2024,
author = {Köhler, Niklas Alexander and Geis, Marcel and Nöh, Claudius and Mielke, Alexandra and Groß, Volker and Lange, Robert and Sohrabi, Keywan and Frey, Jochen},
title = {Key Parameters for Performance and Resilience Modeling of 3D Time-of-Flight Cameras Under Consideration of Signal-to-Noise Ratio and Phase Noise Wiggling},
journal = {Sensors},
year = {2024},
volume = {25},
number = {1},
pages = {109},
doi = {10.3390/s25010109}
}
EUVIMED