Concentration vs. Optical Density of ESKAPEE Bacteria: A Method to Determine the Optimum Measurement Wavelength
Sensors · 21.12.2024 · 24 (24) · 8160
DOI: 10.3390/s24248160 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 21.12.2024. Verfasst von Bruno Wacogne und 9 weiteren Autor:innen. Beteiligte Einrichtung: Institut FEMTO-ST, Université de Franche-Comté, CNRS, F-25000 Besançon, France. Hauptthemen laut MEDLINE: Acinetobacter baumannii, Enterococcus faecium. Die Arbeit wurde bisher 32-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union, EU.
Abstract (Originalsprache)
Optical density measurement has been used for decades to determine the microorganism concentration and more rarely for mammalian cells. Although this measurement can be carried out at any wavelength, studies report a limited number of measurement wavelengths, mainly around 600 nm, and no consensus seems to be emerging to propose an objective method for determining the optimum measurement wavelength for each microorganism. In this article, we propose a method for analyzing the absorbance spectra of ESKAPEE bacteria and determining the optimum measurement wavelength for each of them. The method is based on the analysis of the signal-to-noise ratio of the relationships between concentrations and optical densities when the measurement wavelength varies over the entire spectral range of the absorbance spectra measured for each bacterium. These optimum wavelengths range from 612 nm for Enterococcus faecium to 705 nm for Acinetobacter baumannii. The method can be directly applied to any bacteria, any culture method, and also to any biochemical substance with an absorbance spectrum without any particular feature such as an identified maximum.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institut FEMTO-ST, Université de Franche-Comté, CNRS, F-25000 Besançon, France.
- Centre d'Investigation Clinique, Centre Hospitalier Universitaire de Besançon, INSERM CIC 1431, 25030 Besançon, France.
- Smaltis, Bioinnovation, Rue Charles Bried, 25030 Besançon, France.
ORCID-Profile: Annie Frelet-Barrand
Förderung
- European Union
- EU
Zitieren
APA
Wacogne, B., Belinger Podevin, M., Vaccari, N., Koubevi, C., Codjiová, C., Gutierrez, E., Davoine, L., Robert-Nicoud, M., Rouleau, A., & Frelet-Barrand, A. (2024). Concentration vs. Optical Density of ESKAPEE Bacteria: A Method to Determine the Optimum Measurement Wavelength. Sensors, 24(24), 8160. https://doi.org/10.3390/s24248160
Vancouver
Wacogne B, Belinger Podevin M, Vaccari N, Koubevi C, Codjiová C, Gutierrez E, et al. Concentration vs. Optical Density of ESKAPEE Bacteria: A Method to Determine the Optimum Measurement Wavelength. Sensors. 2024;24(24):8160. doi:10.3390/s24248160
BibTeX
@article{Wacogne2024,
author = {Wacogne, Bruno and Belinger Podevin, Marine and Vaccari, Naïs and Koubevi, Claudia and Codjiová, Céline and Gutierrez, Emilie and Davoine, Lucie and Robert-Nicoud, Marjorie and Rouleau, Alain and Frelet-Barrand, Annie},
title = {Concentration vs. Optical Density of ESKAPEE Bacteria: A Method to Determine the Optimum Measurement Wavelength},
journal = {Sensors},
year = {2024},
volume = {24},
number = {24},
pages = {8160},
doi = {10.3390/s24248160}
}
EUVIMED