Design and Study of Pulsed Eddy Current Sensor for Detecting Surface Defects in Small-Diameter Bars
Sensors · 18.12.2024 · 24 (24) · 8063
DOI: 10.3390/s24248063 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 18.12.2024. Verfasst von Lei Han und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Electrical Engineering, Nanjing Vocational University of Industry Technology, Nanjing 210023, China. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Start-up Fund for New Talented Researchers of Nanjing Vocational University of Industry Technology, the Open Foundation of Industrial Perception and Intelligent Manufacturing Equipment Engineering Research Center of Jiangsu Province, Open Foundation of Industrial Perception and Intelligent Manufacturing Equipment Engineering Research Center of Jiangsu Province.
Abstract (Originalsprache)
The design and study of pulsed eddy current sensors for detecting surface defects in small-diameter rods are highly significant. Accurate detection and identification of surface defects in small-diameter rods may be attained by the ongoing optimization of sensor design and enhancement of detection technologies. This article presents the construction of a non-coaxial differential eddy current sensor (Tx-Rx sensor) and examines the detection of surface defects in a small diameter bar. A COMSOL 3D model is developed to examine the variations in eddy current distribution and defect signal characteristics between the plate and rod components. The position of the excitation coil on the bar and the eddy current disruption around the defect are examined. Additionally, a Tx-Rx sensor has been developed and enhanced concerning coil dimensions, coil separation, and elevation height. An experimental system is established to detect bar structures with surface defects of varying depths, and a model correlating differential signal attenuation with defect depth is proposed, achieving a quantitative relative error of less than 5%, thereby offering a reference for the quantitative detection of bar surface defects.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Electrical Engineering, Nanjing Vocational University of Industry Technology, Nanjing 210023, China.
- College of Automation & College of Artificial Intelligence, Nanjing University of Posts and Telecommunications, Nanjing 210023, China.
ORCID-Profile: Ming Yuan
Förderung
- Start-up Fund for New Talented Researchers of Nanjing Vocational University of Industry Technology
- the Open Foundation of Industrial Perception and Intelligent Manufacturing Equipment Engineering Research Center of Jiangsu Province
- Open Foundation of Industrial Perception and Intelligent Manufacturing Equipment Engineering Research Center of Jiangsu Province
Zitieren
APA
Han, L., Jiang, Y., & Yuan, M. (2024). Design and Study of Pulsed Eddy Current Sensor for Detecting Surface Defects in Small-Diameter Bars. Sensors, 24(24), 8063. https://doi.org/10.3390/s24248063
Vancouver
Han L, Jiang Y, Yuan M. Design and Study of Pulsed Eddy Current Sensor for Detecting Surface Defects in Small-Diameter Bars. Sensors. 2024;24(24):8063. doi:10.3390/s24248063
BibTeX
@article{Han2024,
author = {Han, Lei and Jiang, Yi and Yuan, Ming},
title = {Design and Study of Pulsed Eddy Current Sensor for Detecting Surface Defects in Small-Diameter Bars},
journal = {Sensors},
year = {2024},
volume = {24},
number = {24},
pages = {8063},
doi = {10.3390/s24248063}
}
EUVIMED