EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Peripheral Hemodynamics Estimation Using the Photoplethysmography Method

Toru Shimuta, Kaname Hanada, Kazuteru Ryu, Koichi Idei, Nobuyuki Kanai

Sensors · 2024

DOI: 10.3390/s24247882 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Toru Shimuta und 4 weiteren Autor:innen. Beteiligte Einrichtung: Minato MIRAI Innovation Center, Murata Manufacturing Co., Ltd., 4-3-8, Minatomirai, Nishi-ku, Yokohama-shi 220-0012, Japan. Hauptthemen laut MEDLINE: Photoplethysmography, Hemodynamics. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Diabetes is known to reduce blood circulation in capillaries and arterioles; however, no devices can easily measure this on a daily basis. In this study, we developed a tool for measuring finger photoplethysmograms using green light and near-infrared LEDs. Thereafter, photoplethysmography was conducted on 25 inpatients/outpatients with diabetes and 21 adult males and females who had not been diagnosed with or treated for diabetes, hypertension, or cardiovascular disease (control group). In patients with diabetes, the inverse full width at half-maximum velocity plethysmogram tended to be smaller than that in the control group, and the delay in the green light a-wave peak relative to the near-infrared light a-wave peak in the acceleration plethysmogram was significantly increased. The results suggest that peripheral hemodynamics can be easily estimated at home using a photoplethysmography device mounted on a ring-wearable device.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotoplethysmographyHemodynamicsHumansMaleFemaleMiddle AgedAdultAgedDiabetes Mellitus

Stichwörter der Autor:innen

finger photoplethysmogramperipheral hemodynamicsphotoplethysmography devicephotoplethysmography methodring-wearable device

Autor:innen und Institutionen

  • Minato MIRAI Innovation Center, Murata Manufacturing Co., Ltd., 4-3-8, Minatomirai, Nishi-ku, Yokohama-shi 220-0012, Japan.
  • Orthopedic Surgery, Kanai Hospital, 612-12, Yodokizu-cho, Fushimi-ku, Kyoto 613-0911, Japan.
  • Internal Medicine, Kanai Hospital, 612-12, Yodokizu-cho, Fushimi-ku, Kyoto 613-0911, Japan.

Zitieren

APA

Shimuta, T., Hanada, K., Ryu, K., Idei, K., & Kanai, N. (2024). Peripheral Hemodynamics Estimation Using the Photoplethysmography Method. Sensors. https://doi.org/10.3390/s24247882

Vancouver

Shimuta T, Hanada K, Ryu K, Idei K, Kanai N. Peripheral Hemodynamics Estimation Using the Photoplethysmography Method. Sensors. 2024. doi:10.3390/s24247882

BibTeX
@article{Shimuta2024,
  author = {Shimuta, Toru and Hanada, Kaname and Ryu, Kazuteru and Idei, Koichi and Kanai, Nobuyuki},
  title = {Peripheral Hemodynamics Estimation Using the Photoplethysmography Method},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24247882}
}
Kostenlos starten →