Progressive and Asymmetrical Deadlift Loads Captured by Wearable Motion Tape Sensors
Sensors · 2024
DOI: 10.3390/s24237700 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Elijah Wyckoff und 3 weiteren Autor:innen. Beteiligte Einrichtung: Active, Responsive, Multifunctional, and Ordered-Materials Research (ARMOR) Laboratory, Department of Structural Engineering, University of Californi…. Hauptthemen laut MEDLINE: Wearable Electronic Devices. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science Foundation, U.S. National Science Foundation (NSF), U.S. Office of Naval Research (ONR).
Abstract (Originalsprache)
Weight training is widely adopted and highly effective for enhancing both muscular strength and endurance. A popular weightlifting exercise is the deadlift, which targets multiple muscle groups including the lower back, glutes, and hamstrings. However, incorrect technique (i.e., poor form) can slow training progress, result in asymmetrical muscle development, and cause serious injuries. The objective of this study was to validate that a self-adhesive, elastic fabric, wearable, skin-strain sensor called Motion Tape (MT) could monitor a person’s posture while performing deadlift exercises. Two pairs of Motion Tape were attached on the front and back sides of the pelvis at each posterior superior iliac spine to record muscle engagement during deadlift exercises. The results of this preliminary study confirmed that the MT identified asymmetry in muscle engagement during deadlifting repetitions. In addition, the sensors could quantify the different levels of effort exerted according to the deadlift weight load.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Active, Responsive, Multifunctional, and Ordered-Materials Research (ARMOR) Laboratory, Department of Structural Engineering, University of California San Diego, La Jolla, CA 92093, USA.
- S10 Fitness, San Diego, CA 92110, USA.
ORCID-Profile: Kenneth J Loh
Förderung
- National Science Foundation
- U.S. National Science Foundation (NSF)
- U.S. Office of Naval Research (ONR)
Zitieren
APA
Wyckoff, E., Sten, D., Wareham, R., & Loh, K. J. (2024). Progressive and Asymmetrical Deadlift Loads Captured by Wearable Motion Tape Sensors. Sensors. https://doi.org/10.3390/s24237700
Vancouver
Wyckoff E, Sten D, Wareham R, Loh KJ. Progressive and Asymmetrical Deadlift Loads Captured by Wearable Motion Tape Sensors. Sensors. 2024. doi:10.3390/s24237700
BibTeX
@article{Wyckoff2024,
author = {Wyckoff, Elijah and Sten, David and Wareham, Regan and Loh, Kenneth J},
title = {Progressive and Asymmetrical Deadlift Loads Captured by Wearable Motion Tape Sensors},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24237700}
}