Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Shigeru Tada und 1 weiteren Autor:innen. Beteiligte Einrichtung: National Defense Academy, Yokosuka 239-8686, Japan. Hauptthemen laut MEDLINE: Electrodes, Electrophoresis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Various types of dielectrophoresis (DEP) cell separation devices using AC electric fields have been proposed and developed. However, its capability is still limited by a lack of quantitative characterization of the relationship between frequency and force. In the present study, this limitation was addressed by developing a method capable of fast and accurate quantification of the dielectric properties of biological cells. A newly designed Creek-gap electrode device can induce constant DEP forces on cells, realizing the isomotive movement of cells suitable for DEP analysis. The real number part of the Clausius–Mossotti (CM) factor of cells, Re(β), was obtained by simple cell velocimetry together with the numerical three-dimensional (3D) electric field analysis. Human mammary cells, MCF10A, and its cancer cells, MCF7 and MDAMB231, were used as model cells to evaluate the capability of the proposed device. The estimation of Re(β) using the Creek-gap electrode device showed good agreement with previously reported values. Furthermore, the thermal behavior of the Creek-gap electrode device, which is crucial to cell viability, was investigated by adopting micro laser-induced fluorescence (LIF) thermometry using Rhodamine B. The temperature rise in the device was found to be approximately several degrees Celsius at most. The results demonstrate that the proposed method could be a powerful tool for fast and accurate noninvasive measurement of the DEP spectrum and the determination of the dielectric properties of biological cells.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectrodesElectrophoresisHumansCell SeparationMCF-7 CellsCell Line, Tumor

Stichwörter der Autor:innen

AC nonuniform electric fieldClausius–Mossotti factorcell manipulationdielectrophoresisisomotive movement of cell

Autor:innen und Institutionen

  • National Defense Academy, Yokosuka 239-8686, Japan.
  • Graduate School of Applied Science and Engineering, National Defense Academy, Yokosuka 239-8686, Japan.

Zitieren

APA

Tada, S., & Sato, N. (2024). Analysis of Cell Dielectrophoretic Properties Using Isomotive Creek-Gap Electrode Device. Sensors. https://doi.org/10.3390/s24237681

Vancouver

Tada S, Sato N. Analysis of Cell Dielectrophoretic Properties Using Isomotive Creek-Gap Electrode Device. Sensors. 2024. doi:10.3390/s24237681

BibTeX
@article{Tada2024,
  author = {Tada, Shigeru and Sato, Noriko},
  title = {Analysis of Cell Dielectrophoretic Properties Using Isomotive Creek-Gap Electrode Device},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24237681}
}
Kostenlos starten →