EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparison of Velocity and Estimated One Repetition Maximum Measured with Different Measuring Tools in Bench Presses and Squats

Roland van den Tillaar iD, Hallvard Nygaard Falch, Stian Larsen

Sensors · 2024

DOI: 10.3390/s24237422 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Sensors, 2024. Verfasst von Roland van den Tillaar und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Sport Sciences and Physical Education, Nord University, 7600 Levanger, Norway. Hauptthemen laut MEDLINE: Weight Lifting, Resistance Training. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The aim of this study was to compare barbell velocities at different intensities and estimated 1-RM with actual 1-RM measured with different measuring tools in bench presses and squats. Fourteen resistance-trained athletes (eight men, six women, age 28.1 ± 7.5 years, body mass 78.1 ± 12.2 kg, body height 1.73 ± 0.09 m) performed bench presses and squats at five loads varying from 45 to 85% of one repetition maximum (1-RM), together with 1-RM testing, while measuring mean, mean propulsive, and peak barbell velocity with six different commercially used inertial measurement units (IMUs) and linear encoder software systems attached to the barbell. The 1-RM was also estimated based upon the load–velocity regression, which was compared with the actual 1-RM in the bench press and squat exercises. The main findings were that GymAware revealed the highest reliability along with minimal bias, while Musclelab and Vmaxpro showed moderate reliability with some variability at higher loads. Speed4lifts and PUSH band indicated greater variability, specifically at higher intensities. Furthermore, in relation to the second aim of the study, significant discrepancies were found between actual and estimated 1-RM values, with Speed4lifts and Musclelab notably underestimating 1-RM. These findings underscore the importance of selecting reliable tools for accurate velocity-based training and load prescription.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Weight LiftingResistance TrainingHumansMaleFemaleAdultYoung AdultAthletesBiomechanical PhenomenaMuscle Strength

Stichwörter der Autor:innen

1-RMmean propulsive velocitymean velocitypeak velocityresistance trainingstrength

Autor:innen und Institutionen

  • Department of Sport Sciences and Physical Education, Nord University, 7600 Levanger, Norway.

ORCID-Profile: Roland van den Tillaar

Zitieren

APA

van den Tillaar, R., Nygaard Falch, H., & Larsen, S. (2024). Comparison of Velocity and Estimated One Repetition Maximum Measured with Different Measuring Tools in Bench Presses and Squats. Sensors. https://doi.org/10.3390/s24237422

Vancouver

van den Tillaar R, Nygaard Falch H, Larsen S. Comparison of Velocity and Estimated One Repetition Maximum Measured with Different Measuring Tools in Bench Presses and Squats. Sensors. 2024. doi:10.3390/s24237422

BibTeX
@article{vandenTillaar2024,
  author = {van den Tillaar, Roland and Nygaard Falch, Hallvard and Larsen, Stian},
  title = {Comparison of Velocity and Estimated One Repetition Maximum Measured with Different Measuring Tools in Bench Presses and Squats},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24237422}
}
Kostenlos starten →