Detection of Low-Density Foreign Objects in Infant Snacks Using a Continuous-Wave Sub-Terahertz Imaging System for Industrial Applications
Sensors · 19.11.2024 · 24 (22) · 7374
DOI: 10.3390/s24227374 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 19.11.2024. Verfasst von Byeong-Hyeon Na und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Food Science and Biotechnology, Kyungpook National University, Daegu 41566, Republic of Korea. Hauptthemen laut MEDLINE: Snacks. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Food and Drug Safety, Ministry of Food and Drug Safety of Korea, DGIST research 373.
Abstract (Originalsprache)
Low-density foreign objects (LDFOs) in foods pose significant safety risks to consumers. Existing detection methods, such as metal and X-ray detectors, have limitations in identifying low-density and nonmetallic contaminants. To address these challenges, our research group constructed and optimized a continuous-wave sub-terahertz (THz) imaging system for the real-time, on-site detection of LDFOs in infant snacks. The system was optimized by adjusting the attenuation value from 0 to 9 dB and image processing parameters [White (W), Black (B), and Gamma (G)] from 0 to 100. Its detectability was evaluated across eight LDFOs underneath snacks with scanning at 30 cm/s. The optimal settings for puffed snacks and freeze-dried chips were found to be 3 dB attenuation with W, B, and G values of 100, 50, and 80, respectively, while others required 0 dB attenuation with W, B, and G set to 100, 0, and 100, respectively. Additionally, the moisture content of infant snacks was measured using a modified AOAC-based drying method at 105 °C, ensuring the removal of all free moisture. Using these optimized settings, the system successfully detected a housefly and a cockroach underneath puffed snacks and freeze-dried chips. It also detected LDFOs as small as 3 mm in size in a single layer of snacks, including polyurethane, polyvinyl chloride, ethylene–propylene–diene–monomer, and silicone, while in two layers of infant snacks, they were detected up to 7.5 mm. The constructed system can rapidly and effectively detect LDFOs in foods, offering a promising approach to enhance safety in the food industry.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Food Science and Biotechnology, Kyungpook National University, Daegu 41566, Republic of Korea.
- ICT Research Institute, Daegu Gyeongbuk Institute of Science & Technology (DGIST), Daegu 42988, Republic of Korea.
ORCID-Profile: Mi-Kyung Park
Förderung
- Ministry of Food and Drug Safety
- Ministry of Food and Drug Safety of Korea
- DGIST research 373
Zitieren
APA
Na, B. H., Lee, D. H., Choe, J., Kim, Y. D., & Park, M. K. (2024). Detection of Low-Density Foreign Objects in Infant Snacks Using a Continuous-Wave Sub-Terahertz Imaging System for Industrial Applications. Sensors, 24(22), 7374. https://doi.org/10.3390/s24227374
Vancouver
Na BH, Lee DH, Choe J, Kim YD, Park MK. Detection of Low-Density Foreign Objects in Infant Snacks Using a Continuous-Wave Sub-Terahertz Imaging System for Industrial Applications. Sensors. 2024;24(22):7374. doi:10.3390/s24227374
BibTeX
@article{Na2024,
author = {Na, Byeong-Hyeon and Lee, Dae-Ho and Choe, Jaein and Kim, Young-Duk and Park, Mi-Kyung},
title = {Detection of Low-Density Foreign Objects in Infant Snacks Using a Continuous-Wave Sub-Terahertz Imaging System for Industrial Applications},
journal = {Sensors},
year = {2024},
volume = {24},
number = {22},
pages = {7374},
doi = {10.3390/s24227374}
}
EUVIMED