Validation of Multi-Frequency Inductive-Loop Measurement System for Parameters of Moving Vehicle Based on Laboratory Model
Sensors · 13.11.2024 · 24 (22) · 7244
DOI: 10.3390/s24227244 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 13.11.2024. Verfasst von Zbigniew Marszalek und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Measurement and Electronics, AGH University of Krakow, 30 Mickiewicz Avenue, 30-059 Krakow, Poland. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The paper presents research on a system for measuring the parameters of a vehicle in motion and the process of validating it under laboratory conditions. The measurement system uses four inductive-loop (IL) sensors, two slim ILs and two wide ILs. The vehicle speed, wheelbase, length, and overhangs are all determined on the basis of a vehicle magnetic profile (VMP) waveform. VMPs are captured from the continuous IL-based impedance measurement. The impedance measurement for a single IL is performed simultaneously at three carrier frequencies. The uncontrolled measurement conditions in the field on a real road test bed (RTB), including the speed of passing vehicles, motivated the development of a laboratory test bed (LTB). This LTB serves as a model of an existing measurement setup installed on the road, i.e., the RTB. The LTB includes IL sensors and a movable model of the vehicle made in 1:50 scale. The LTB enables validation of the whole measurement system in the vehicle speed range from 10 km/h up to 150 km/h in 5 km/h increments in fully controlled conditions. The measurement results are presented in the distance domain, calculated from the VMPs and the measured speed. The largest errors in estimating vehicle-model body parameters, on a natural scale, do not exceed 4.3 cm.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Measurement and Electronics, AGH University of Krakow, 30 Mickiewicz Avenue, 30-059 Krakow, Poland.
ORCID-Profile: Zbigniew Marszalek, Krzysztof Duda
Zitieren
APA
Marszalek, Z., & Duda, K. (2024). Validation of Multi-Frequency Inductive-Loop Measurement System for Parameters of Moving Vehicle Based on Laboratory Model. Sensors, 24(22), 7244. https://doi.org/10.3390/s24227244
Vancouver
Marszalek Z, Duda K. Validation of Multi-Frequency Inductive-Loop Measurement System for Parameters of Moving Vehicle Based on Laboratory Model. Sensors. 2024;24(22):7244. doi:10.3390/s24227244
BibTeX
@article{Marszalek2024,
author = {Marszalek, Zbigniew and Duda, Krzysztof},
title = {Validation of Multi-Frequency Inductive-Loop Measurement System for Parameters of Moving Vehicle Based on Laboratory Model},
journal = {Sensors},
year = {2024},
volume = {24},
number = {22},
pages = {7244},
doi = {10.3390/s24227244}
}