Evaluating Alternative Registration Planes in Imageless, Computer-Assisted Navigation Systems for Direct Anterior Total Hip Arthroplasty
Sensors · 2024
DOI: 10.3390/s24217092 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von John E Farey und 7 weiteren Autor:innen. Beteiligte Einrichtung: Sydney Musculoskeletal Health, Kolling Institute, Northern Clinical School, Faculty of Medicine and Health, University of Sydney, Camperdown, NSW 206…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Surgery, Computer-Assisted, Acetabulum. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
(1)
Background
Imageless computer navigation systems have the potential to improve the accuracy of acetabular cup position in total hip arthroplasty (THA). Popular imageless navigation methods include locating the patient in a three-dimensional space (registration method) while using a baseline to angle the acetabular cup (reference plane). This study aims to compare the accuracy of different methods for determining postoperative acetabular cup positioning in THA via the direct anterior approach. (2)
Methods
Fifty-one participants were recruited. Optical and inertial sensor imageless navigation systems were used simultaneously with three combinations of registration methods and reference planes: the anterior pelvic plane (APP), the anterior superior iliac spine (ASIS) and the table tilt (TT) method. Postoperative acetabular cup position, inclination, and anteversion were assessed using CT scans. (3)
Results
For inclination, the mean absolute error (MAE) was lower using the TT method (2.4° ± 1.7°) compared to the ASIS (2.8° ± 1.7°, p = 0.17) and APP method (3.7° ± 2.1°, p < 0.001). For anteversion, the MAE was significantly lower for the TT method (2.4° ± 1.8°) in contrast to the ASIS (3.9° ± 3.2°, p = 0.005) and APP method (9.1° ± 6.2°, p < 0.001). (4)
Conclusion
A functional reference plane is superior to an anatomic reference plane to accurately measure intraoperative acetabular cup inclination and anteversion in THA using inertial imageless navigation systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Sydney Musculoskeletal Health, Kolling Institute, Northern Clinical School, Faculty of Medicine and Health, University of Sydney, Camperdown, NSW 2064, Australia.
- Institute of Future Health, South China University of Technology, Guangzhou 511442, China.
- Department of Orthopedics and Traumatic Surgery, Royal North Shore Hospital, St Leonards, NSW 2065, Australia.
- Department of Orthopedic Surgery, University Hospitals Leuven, Herestraat 49, 3000 Leuven, Belgium.
- Innovation Department, Navbit, Sydney, NSW 2000, Australia.
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, NY 10021, USA.
ORCID-Profile: Yuan Chai, Joshua Xu, Vincent Maes
Zitieren
APA
Farey, J. E., Chai, Y., Xu, J., Maes, V., Sadeghpour, A., Baker, N. A., Vigdorchik, J. M., & Walter, W. L. (2024). Evaluating Alternative Registration Planes in Imageless, Computer-Assisted Navigation Systems for Direct Anterior Total Hip Arthroplasty. Sensors. https://doi.org/10.3390/s24217092
Vancouver
Farey JE, Chai Y, Xu J, Maes V, Sadeghpour A, Baker NA, et al. Evaluating Alternative Registration Planes in Imageless, Computer-Assisted Navigation Systems for Direct Anterior Total Hip Arthroplasty. Sensors. 2024. doi:10.3390/s24217092
BibTeX
@article{Farey2024,
author = {Farey, John E and Chai, Yuan and Xu, Joshua and Maes, Vincent and Sadeghpour, Ameneh and Baker, Neri A and Vigdorchik, Jonathan M and Walter, William L},
title = {Evaluating Alternative Registration Planes in Imageless, Computer-Assisted Navigation Systems for Direct Anterior Total Hip Arthroplasty},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24217092}
}