EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

LIG-Based High-Sensitivity Multiplexed Sensing System for Simultaneous Monitoring of Metabolites and Electrolytes

Sang Hyun Park iD, James Jungho Pak iD

Sensors · 2024

DOI: 10.3390/s24216945 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Sang Hyun Park und 1 weiteren Autor:innen. Beteiligte Einrichtung: School of Electrical Engineering, Korea University, Seoul 02841, Republic of Korea. Hauptthemen laut MEDLINE: Biosensing Techniques, Electrolytes. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 85 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science and ICT, R&D program of MOTIE/KEIT, National Research Foundation of Korea (NRF).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

With improvements in medical environments and the widespread use of smartphones, interest in wearable biosensors for continuous body monitoring is growing. We developed a wearable multiplexed bio-sensing system that non-invasively monitors body fluids and integrates with a smartphone application. The system includes sensors, readout circuits, and a microcontroller unit (MCU) for signal processing and wireless communication. Potentiometric and amperometric measurement methods were used, with calibration capabilities added to ensure accurate readings of analyte concentrations and temperature. Laser-induced graphene (LIG)-based sensors for glucose, lactate, Na+, K+, and temperature were developed for fast, cost-effective production. The LIG electrode’s 3D porous structure provided an active surface area 16 times larger than its apparent area, resulting in enhanced sensor performance. The glucose and lactate sensors exhibited high sensitivity (168.15 and 872.08 μAmM−1cm−2, respectively) and low detection limits (0.191 and 0.167 μM, respectively). The Na+ and K+ sensors demonstrated sensitivities of 65.26 and 62.19 mVdec−1, respectively, in a concentration range of 0.01–100 mM. Temperature sensors showed an average rate of resistance change per °C of 0.25%/°C, within a temperature range of 20–40 °C, providing accurate body temperature monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesElectrolytesHumansGlucoseSmartphoneGraphiteLactic AcidTemperatureWearable Electronic DevicesElectrodesMonitoring, PhysiologicPotassiumSodiumLimit of Detection

Stichwörter der Autor:innen

K+ sensorNa+ sensorglucose sensorlactate sensorlaser-induced graphenewearable biosensor

Substanzen

ElectrolytesGlucoseGraphiteLactic AcidPotassiumSodium

Autor:innen und Institutionen

  • School of Electrical Engineering, Korea University, Seoul 02841, Republic of Korea.

ORCID-Profile: Sang Hyun Park, James Jungho Pak

Förderung

  • Ministry of Science and ICT
  • R&D program of MOTIE/KEIT
  • National Research Foundation of Korea (NRF)

Zitieren

APA

Park, S. H., & Pak, J. J. (2024). LIG-Based High-Sensitivity Multiplexed Sensing System for Simultaneous Monitoring of Metabolites and Electrolytes. Sensors. https://doi.org/10.3390/s24216945

Vancouver

Park SH, Pak JJ. LIG-Based High-Sensitivity Multiplexed Sensing System for Simultaneous Monitoring of Metabolites and Electrolytes. Sensors. 2024. doi:10.3390/s24216945

BibTeX
@article{Park2024,
  author = {Park, Sang Hyun and Pak, James Jungho},
  title = {LIG-Based High-Sensitivity Multiplexed Sensing System for Simultaneous Monitoring of Metabolites and Electrolytes},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24216945}
}
Kostenlos starten →