LIG-Based High-Sensitivity Multiplexed Sensing System for Simultaneous Monitoring of Metabolites and Electrolytes
Sensors · 2024
DOI: 10.3390/s24216945 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Sang Hyun Park und 1 weiteren Autor:innen. Beteiligte Einrichtung: School of Electrical Engineering, Korea University, Seoul 02841, Republic of Korea. Hauptthemen laut MEDLINE: Biosensing Techniques, Electrolytes. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 85 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science and ICT, R&D program of MOTIE/KEIT, National Research Foundation of Korea (NRF).
Abstract (Originalsprache)
With improvements in medical environments and the widespread use of smartphones, interest in wearable biosensors for continuous body monitoring is growing. We developed a wearable multiplexed bio-sensing system that non-invasively monitors body fluids and integrates with a smartphone application. The system includes sensors, readout circuits, and a microcontroller unit (MCU) for signal processing and wireless communication. Potentiometric and amperometric measurement methods were used, with calibration capabilities added to ensure accurate readings of analyte concentrations and temperature. Laser-induced graphene (LIG)-based sensors for glucose, lactate, Na+, K+, and temperature were developed for fast, cost-effective production. The LIG electrode’s 3D porous structure provided an active surface area 16 times larger than its apparent area, resulting in enhanced sensor performance. The glucose and lactate sensors exhibited high sensitivity (168.15 and 872.08 μAmM−1cm−2, respectively) and low detection limits (0.191 and 0.167 μM, respectively). The Na+ and K+ sensors demonstrated sensitivities of 65.26 and 62.19 mVdec−1, respectively, in a concentration range of 0.01–100 mM. Temperature sensors showed an average rate of resistance change per °C of 0.25%/°C, within a temperature range of 20–40 °C, providing accurate body temperature monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Electrical Engineering, Korea University, Seoul 02841, Republic of Korea.
ORCID-Profile: Sang Hyun Park, James Jungho Pak
Förderung
- Ministry of Science and ICT
- R&D program of MOTIE/KEIT
- National Research Foundation of Korea (NRF)
Zitieren
APA
Park, S. H., & Pak, J. J. (2024). LIG-Based High-Sensitivity Multiplexed Sensing System for Simultaneous Monitoring of Metabolites and Electrolytes. Sensors. https://doi.org/10.3390/s24216945
Vancouver
Park SH, Pak JJ. LIG-Based High-Sensitivity Multiplexed Sensing System for Simultaneous Monitoring of Metabolites and Electrolytes. Sensors. 2024. doi:10.3390/s24216945
BibTeX
@article{Park2024,
author = {Park, Sang Hyun and Pak, James Jungho},
title = {LIG-Based High-Sensitivity Multiplexed Sensing System for Simultaneous Monitoring of Metabolites and Electrolytes},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24216945}
}