Two-Step Iterative Medical Microwave Tomography
Sensors · 2024
DOI: 10.3390/s24216897 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Zekun Zhang und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Information and Electronics, Beijing Institute of Technology, Beijing 100081, China. Hauptthemen laut MEDLINE: Algorithms, Tomography, Microwaves. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Jiaxing Key Research and Development Program, Open Project Program of Key Laboratory of Medical Electronics and Digital Health of Zhejiang Province, Swedish National funding Vetenskapsrådets “HI-CORE” project.
Abstract (Originalsprache)
In the field of medical imaging, microwave tomography (MWT) is based on the scattering and absorption characteristics of different tissues to microwaves and can reconstruct the electromagnetic property distribution of biological tissues non-invasively and without ionizing radiation. However, due to the inherently nonlinear and ill-posed characteristics of MWT calculations, actual imaging is prone to overfitting or artifacts. To address this, this paper proposes a two-step iterative imaging approach for rapid medical microwave tomography. This method establishes corresponding objective functions for microwave imaging across multiple frequencies and conducts iterative calculations on images at varying resolutions. This effectively enhances image clarity and accuracy while alleviating the issue of prolonged computational time associated with imaging complex structures at high resolution due to insufficient prior information during iterative processes. In the electromagnetic simulation section, we simulated a three-layer brain model and conducted imaging experiments. The results demonstrate that the algorithm significantly enhances imaging resolution, accurately pinpointing cerebral hemorrhages at different locations using an eight-antenna array and successfully reconstructs tomography images with a hemorrhage area radius of 1 cm. Lastly, experiments were conducted using a medical microwave tomography platform and four simplified human brain models, achieving millimeter-level accuracy in MWT.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Information and Electronics, Beijing Institute of Technology, Beijing 100081, China.
- School of Cyberspace Science and Technology, Beijing Institute of Technology, Beijing 100081, China.
- Chalmers Industriteknik, 412 58 Göteborg, Sweden.
- Sydney Smart Technology College, Northeastern University at Qinhuangdao, Qinhuangdao 066004, China.
- Department of Neurosurgery, The First Medical Center of PLA General Hospital, Beijing 100853, China.
ORCID-Profile: Xiang Gao
Förderung
- Jiaxing Key Research and Development Program
- Open Project Program of Key Laboratory of Medical Electronics and Digital Health of Zhejiang Province
- Swedish National funding Vetenskapsrådets “HI-CORE” project
Zitieren
APA
Zhang, Z., Liu, H., Gao, X., Zhang, Z., He, Z. S., Liu, L., Zong, R., & Qin, Z. (2024). Two-Step Iterative Medical Microwave Tomography. Sensors. https://doi.org/10.3390/s24216897
Vancouver
Zhang Z, Liu H, Gao X, Zhang Z, He ZS, Liu L, et al. Two-Step Iterative Medical Microwave Tomography. Sensors. 2024. doi:10.3390/s24216897
BibTeX
@article{Zhang2024,
author = {Zhang, Zekun and Liu, Heng and Gao, Xiang and Zhang, Zeyu and He, Zhongxia Simon and Liu, Luoyuan and Zong, Rui and Qin, Zhizhen},
title = {Two-Step Iterative Medical Microwave Tomography},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24216897}
}
EUVIMED