Fachartikel in der Zeitschrift Sensors, online erschienen am 18.10.2024. Verfasst von Meirbek Mussatayev und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Electrical, Electronic and Mechanical Engineering, University of Bristol, Bristol BS8 1TR, UK. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In the field of railroad safety, the effective detection of surface cracks is critical, necessitating reliable, high-speed, non-destructive testing (NDT) methods. This study introduces a hybrid Eddy Current Testing (ECT) probe, specifically engineered for railroad inspection, to address the common issue of “lift-off noise” due to varying distances between the probe and the test material. Unlike traditional ECT methods, this probe integrates transmit and differential receiver (Tx-dRx) coils, aiming to enhance detection sensitivity and minimise the lift-off impact. The study optimises ECT probes employing different transmitter coils, emphasising three main objectives: (a) quantitatively evaluating each probe using signal-to-noise ratio (SNR) and outlining a real-time data-processing algorithm based on SNR methodology; (b) exploring the frequency range proximal to the electrical resonance of the receiver coil; and (c) examining sensitivity variations across varying lift-off distances. The experimental outcomes indicate that the newly designed probe with a figure-8 shaped transmitter coil significantly improves sensitivity in detecting surface cracks on railroads. It achieves an impressive SNR exceeding 100 for defects with minimal dimensions of 1 mm in width and depth. The simulation results closely align with experimental findings, validating the investigation of the optimal operational frequency and lift-off distance for selected probe performance, which are determined to be 0.3 MHz and 1 mm, respectively. The realisation of this project would lead to notable advancements in enhancing railroad safety by improving the efficiency of crack detection.

Schlagwörter

Stichwörter der Autor:innen

Eddy Current Testinglift-offnon-destructive testingprobe optimisationreal-time inspectionsignal-to-noise ratio

Autor:innen und Institutionen

  • School of Electrical, Electronic and Mechanical Engineering, University of Bristol, Bristol BS8 1TR, UK.
  • Kazakhstan Institute of Non-Destructive Evaluation LLP, 59, Tole bi Street (KBTU), Almaty 050005/A05H1T2, Kazakhstan.
  • Department of Mechanical Engineering, The University of Sheffield, Mappin Street, Sheffield S1 3JD, UK.
  • Department of Intelligent Manufacturing Engineering, Guilin University of Electronic Technology, Guilin 541004, China.

ORCID-Profile: Meirbek Mussatayev, Ruby Kempka

Zitieren

APA

Mussatayev, M., Kempka, R., & Alanesi, M. (2024). Towards Advancing Real-Time Railroad Inspection Using a Directional Eddy Current Probe. Sensors, 24(20), 6702. https://doi.org/10.3390/s24206702

Vancouver

Mussatayev M, Kempka R, Alanesi M. Towards Advancing Real-Time Railroad Inspection Using a Directional Eddy Current Probe. Sensors. 2024;24(20):6702. doi:10.3390/s24206702

BibTeX
@article{Mussatayev2024,
  author = {Mussatayev, Meirbek and Kempka, Ruby and Alanesi, Mohammed},
  title = {Towards Advancing Real-Time Railroad Inspection Using a Directional Eddy Current Probe},
  journal = {Sensors},
  year = {2024},
  volume = {24},
  number = {20},
  pages = {6702},
  doi = {10.3390/s24206702}
}
Kostenlos starten →