Muscle Oxygen Saturation Dynamics During Upper-Body Resistance Exercise
Sensors · 2024
DOI: 10.3390/s24206668 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Adam M Gonzalez und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Allied Health and Kinesiology, Hofstra University, Hempstead, NY 11549, USA. Hauptthemen laut MEDLINE: Resistance Training, Muscle, Skeletal, Spectroscopy, Near-Infrared. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Research examining the changes in muscle oxygen saturation across multiple sets of resistance exercise is limited. The purpose of this study was to describe the physiological response of muscle oxygenation parameters during upper-body resistance exercise and examine the differential effects of relevant participant characteristics on resistance training performance and muscle oxygen saturation dynamics. Sixty-one recreationally trained men (n = 44; 21.8 ± 2.6 years) and women (n = 17; 20.2 ± 1.8 years) completed five-repetition maximum sets of barbell bench presses at a load equal to 75% 1-RM with a 2 min rest interval. Muscle oxygen saturation (SmO2) dynamics within the anterior deltoid were monitored using a portable near-infrared spectroscopy sensor. The percent change in SmO2 (∆%SmO2), the muscle oxygen re-saturation rate (SmO2RecSlope), and the highest measured SmO2 value during recovery periods (SmO2Peak) were measured. Two-way (sex [men, women] x time [sets 1–5]) repeated measures analyses of variance (ANOVA) were performed on muscle saturation variables. To examine the effect of relevant controlling variables, separate analyses of covariance (ANCOVA) with repeated measures were also performed. No differences were seen with ∆%SmO2 across sets. The main effects for sets occurred for SmO2RecSlope, whereby a decline was noted on sets 4 and 5 (p = 0.001) compared to set 1. Additionally, SmO2Peak was the lowest on set 5 (p < 0.001) compared to all other sets. Moreover, body mass (p = 0.013), diastolic blood pressure (p = 0.044), and mean arterial pressure (p = 0.033) for ∆%SmO2 were the only significant covariates noted amongst the muscle oxygenation variables. In conclusion, no sex differences and only a few set differences in muscle oxygen saturation dynamics were seen without employing any covariates. Body mass, diastolic blood pressure, and mean arterial pressure were identified as factors that could influence observed responses.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Allied Health and Kinesiology, Hofstra University, Hempstead, NY 11549, USA.
- Department of Exercise Science and Sport Management, Kennesaw State University, Kennesaw, GA 30144, USA.
- Program in Exercise Science and Exercise Physiology, Kent State University, Kent, OH 44240, USA.
- Resistance Exercise, Physiology, and Sport Laboratory, Health and Exercise Physiology Department, Ursinus College, Collegeville, PA 19426, USA.
- Research, Nutrition and Innovation, AG1, Carson City, NV 89701, USA.
ORCID-Profile: Gerald T Mangine, Anthony G Pinzone, Kyle S Beyer
Zitieren
APA
Gonzalez, A. M., Mangine, G. T., Pinzone, A. G., Beyer, K. S., & Townsend, J. R. (2024). Muscle Oxygen Saturation Dynamics During Upper-Body Resistance Exercise. Sensors. https://doi.org/10.3390/s24206668
Vancouver
Gonzalez AM, Mangine GT, Pinzone AG, Beyer KS, Townsend JR. Muscle Oxygen Saturation Dynamics During Upper-Body Resistance Exercise. Sensors. 2024. doi:10.3390/s24206668
BibTeX
@article{Gonzalez2024,
author = {Gonzalez, Adam M and Mangine, Gerald T and Pinzone, Anthony G and Beyer, Kyle S and Townsend, Jeremy R},
title = {Muscle Oxygen Saturation Dynamics During Upper-Body Resistance Exercise},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24206668}
}
EUVIMED