EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

High Sensitivity Bi2O3/Ti3C2Tx Ammonia Sensor Based on Improved Synthetic MXene Method at Room Temperature

Baocang Zhou, Zhihua Zhao iD, Zhenli Lv, Zhuo Chen, Sibo Kang

Sensors · 10.10.2024 · 24 (20) · 6514

DOI: 10.3390/s24206514 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 10.10.2024. Verfasst von Baocang Zhou und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Mechanical and Electrical Engineering, Henan University of Technology, Zhengzhou 450052, China. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Technology R&D Program Joint Fund of Henan Provincial Department of Science and Technology, the fund of Henan Key Laboratory of Superhard Abrasives and Grinding Equipment, Henan University of Technology, the Key Research and Development Program of Henan Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The MXene Ti3C2Tx was synthesized using hydrofluoric acid and an improved multilayer method in this study. Subsequently, a Bi2O3/Ti3C2Tx composite material was produced through hydrothermal synthesis. This composite boasts a unique layered structure, offering a large surface area that provides numerous contact and reaction sites, facilitating the adsorption of ammonia on its surface. The prepared Bi2O3/Ti3C2Tx-based sensor exhibits excellent sensing performance for ammonia gas, including high responsiveness, good repeatability, and rapid response–recovery time. The sensor’s response to 100 ppm ammonia gas is 61%, which is 11.3 times and 1.6 times the response values of the Ti3C2Tx gas sensor and Bi2O3 gas sensor, with response/recovery times of 61 s/164 s at room temperature, respectively. Additionally, the gas sensitivity mechanism of the Bi2O3/Ti3C2Tx-based sensor was analyzed, and the gas sensing response mechanism was proposed. This study shows that the sensor can effectively enhance the accuracy and precision of ammonia detection at room temperature and has a wide range of application scenarios.

Schlagwörter

Stichwörter der Autor:innen

Bi2O3MXeneTi3C2Txammonia sensorgas sensors

Autor:innen und Institutionen

  • College of Mechanical and Electrical Engineering, Henan University of Technology, Zhengzhou 450052, China.

ORCID-Profile: Zhihua Zhao

Förderung

  • the Technology R&D Program Joint Fund of Henan Provincial Department of Science and Technology
  • the fund of Henan Key Laboratory of Superhard Abrasives and Grinding Equipment, Henan University of Technology
  • the Key Research and Development Program of Henan Province
  • the Youth Backbone Teacher Training Program of Henan University of Technology
  • the Natural Science Project of Zhengzhou Science and Technology Bureau
  • Technology R&D Program Joint Fund of Henan Provincial Department of Science and Technology
  • Henan Key Laboratory of Superhard Abrasives and Grinding Equipment, Henan University of Technology
  • Key Research and Development Program of Henan Province

Zitieren

APA

Zhou, B., Zhao, Z., Lv, Z., Chen, Z., & Kang, S. (2024). High Sensitivity Bi2O3/Ti3C2Tx Ammonia Sensor Based on Improved Synthetic MXene Method at Room Temperature. Sensors, 24(20), 6514. https://doi.org/10.3390/s24206514

Vancouver

Zhou B, Zhao Z, Lv Z, Chen Z, Kang S. High Sensitivity Bi2O3/Ti3C2Tx Ammonia Sensor Based on Improved Synthetic MXene Method at Room Temperature. Sensors. 2024;24(20):6514. doi:10.3390/s24206514

BibTeX
@article{Zhou2024,
  author = {Zhou, Baocang and Zhao, Zhihua and Lv, Zhenli and Chen, Zhuo and Kang, Sibo},
  title = {High Sensitivity Bi2O3/Ti3C2Tx Ammonia Sensor Based on Improved Synthetic MXene Method at Room Temperature},
  journal = {Sensors},
  year = {2024},
  volume = {24},
  number = {20},
  pages = {6514},
  doi = {10.3390/s24206514}
}
Kostenlos starten →