EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Novel Wearable Sensor for Measuring Respiration Continuously and in Real Time

Amjad Ali iD, Yang Wei iD, Yomna Elsaboni, Jack Tyson, Harry Akerman, Alexander I R Jackson iD, Rod Lane iD, Daniel Spencer iD, Neil M White iD

Sensors · 2024

DOI: 10.3390/s24206513 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Amjad Ali und 8 weiteren Autor:innen. Beteiligte Einrichtung: Smart Wearable Research Group, School of Science and Technology, Nottingham Trent University, Nottingham NG11 8NS, UK. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Respiration. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Institute for Health and Care Research (NIHR).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this work, a flexible textile-based capacitive respiratory sensor, based on a capacitive sensor structure, that does not require direct skin contact is designed, optimised, and evaluated using both computational modelling and empirical measurements. In the computational study, the geometry of the sensor was examined. This analysis involved observing the capacitance and frequency variations using a cylindrical model that mimicked the human body. Four designs were selected which were then manufactured by screen printing multiple functional layers on top of a polyester/cotton fabric. The printed sensors were characterised to detect the performance against phantoms and impacts from artefacts, normally present whilst wearing the device. A sensor that has an electrode ratio of 1:3:1 (sensor, reflector, and ground) was shown to be the most sensitive design, as it exhibits the highest sensitivity of 6.2% frequency change when exposed to phantoms. To ensure the replicability of the sensors, several batches of identical sensors were developed and tested using the same physical parameters, which resulted in the same percentage frequency change. The sensor was further tested on volunteers, showing that the sensor measures respiration with 98.68% accuracy compared to manual breath counting.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wearable Electronic DevicesRespirationHumansMonitoring, PhysiologicTextilesElectrodesBiosensing Techniques

Stichwörter der Autor:innen

electronic textilesrespiratory sensorswearable sensors

Autor:innen und Institutionen

  • Smart Wearable Research Group, School of Science and Technology, Nottingham Trent University, Nottingham NG11 8NS, UK.
  • School of Electronics & Computer Science, University of Southampton, Southampton SO17 1BJ, UK.
  • Clinical Care, University Hospital Southampton NHS Foundation Trust, Southampton SO16 6YD, UK.
  • Perioperative and Critical Care Theme, NIHR Southampton Biomedical Research Centre, University Hospital Southampton NHS Foundation Trust, Southampton SO16 6YD, UK.
  • Integrative Physiology and Critical Illness Group, Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, Southampton SO16 6YD, UK.
  • Zelemiq Ltd., Salisbury SP5 1EZ, UK.

ORCID-Profile: Amjad Ali, Yang Wei, Alexander I R Jackson, Rod Lane, Daniel Spencer, Neil M White

Förderung

  • National Institute for Health and Care Research (NIHR)

Zitieren

APA

Ali, A., Wei, Y., Elsaboni, Y., Tyson, J., Akerman, H., Jackson, A. I. R., Lane, R., Spencer, D., & White, N. M. (2024). A Novel Wearable Sensor for Measuring Respiration Continuously and in Real Time. Sensors. https://doi.org/10.3390/s24206513

Vancouver

Ali A, Wei Y, Elsaboni Y, Tyson J, Akerman H, Jackson AIR, et al. A Novel Wearable Sensor for Measuring Respiration Continuously and in Real Time. Sensors. 2024. doi:10.3390/s24206513

BibTeX
@article{Ali2024,
  author = {Ali, Amjad and Wei, Yang and Elsaboni, Yomna and Tyson, Jack and Akerman, Harry and Jackson, Alexander I R and Lane, Rod and Spencer, Daniel and White, Neil M},
  title = {A Novel Wearable Sensor for Measuring Respiration Continuously and in Real Time},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24206513}
}
Kostenlos starten →