Evaluation of Two Particle Number (PN) Counters with Different Test Protocols for the Periodic Technical Inspection (PTI) of Gasoline Vehicles

Anastasios Melas iD, Jacopo Franzetti iD, Ricardo Suarez-Bertoa iD, Barouch Giechaskiel

Sensors · 10.10.2024 · 24 (20) · 6509

DOI: 10.3390/s24206509 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 10.10.2024. Verfasst von Anastasios Melas und 3 weiteren Autor:innen. Beteiligte Einrichtung: European Commission, Joint Research Centre (JRC), 21027 Ispra, Italy. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 65 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Thousands of particle number (PN) counters have been introduced to the European market, following the implementation of PN tests during the periodic technical inspection (PTI) of diesel vehicles equipped with particulate filters. Expanding the PN-PTI test to gasoline vehicles may face several challenges due to the different exhaust aerosol characteristics. In this study, two PN-PTI instruments, type-examined for diesel vehicles, measured fifteen petrol passenger cars with different test protocols: low and high idling, with or without additional load, and sharp accelerations. The instruments, one based on diffusion charging and the other on condensation particle counting, demonstrated good linearity compared to the reference instrumentation with R-squared values of 0.93 and 0.92, respectively. However, in a considerable number of tests, they registered higher particle concentrations due to the presence of high concentrations below their theoretical 23 nm cut-off size. The evaluation of the different test protocols showed that gasoline direct injection engine vehicles without particulate filters (GPFs) generally emitted an order of magnitude or higher PN compared to those with GPFs. However, high variations in concentration levels were observed for each vehicle. Port-fuel injection vehicles without GPFs mostly emitted PN concentrations near the lower detection limit of the PN-PTI instruments.

Schlagwörter

Stichwörter der Autor:innen

GDIPFIPN-PTIcondensation particle counterdiffusion chargerin-use vehicle emissionspetrol carsub-23 nm particles

Autor:innen und Institutionen

  • European Commission, Joint Research Centre (JRC), 21027 Ispra, Italy.
  • Mining and Energy Engineering School, Universidad Politécnica de Madrid, c/Rios Rosas 21, 28003 Madrid, Spain.

ORCID-Profile: Anastasios Melas, Jacopo Franzetti, Ricardo Suarez-Bertoa

Zitieren

APA

Melas, A., Franzetti, J., Suarez-Bertoa, R., & Giechaskiel, B. (2024). Evaluation of Two Particle Number (PN) Counters with Different Test Protocols for the Periodic Technical Inspection (PTI) of Gasoline Vehicles. Sensors, 24(20), 6509. https://doi.org/10.3390/s24206509

Vancouver

Melas A, Franzetti J, Suarez-Bertoa R, Giechaskiel B. Evaluation of Two Particle Number (PN) Counters with Different Test Protocols for the Periodic Technical Inspection (PTI) of Gasoline Vehicles. Sensors. 2024;24(20):6509. doi:10.3390/s24206509

BibTeX
@article{Melas2024,
  author = {Melas, Anastasios and Franzetti, Jacopo and Suarez-Bertoa, Ricardo and Giechaskiel, Barouch},
  title = {Evaluation of Two Particle Number (PN) Counters with Different Test Protocols for the Periodic Technical Inspection (PTI) of Gasoline Vehicles},
  journal = {Sensors},
  year = {2024},
  volume = {24},
  number = {20},
  pages = {6509},
  doi = {10.3390/s24206509}
}
Kostenlos starten →