EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The Validity of Apple Watch Series 9 and Ultra 2 for Serial Measurements of Heart Rate Variability and Resting Heart Rate

Ben O'Grady iD, Rory Lambe iD, Maximus Baldwin iD, Tara Acheson, Cailbhe Doherty iD

Sensors · 26.09.2024 · 24 (19) · 6220

DOI: 10.3390/s24196220 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 26.09.2024. Verfasst von Ben O'Grady und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Public Health, Physiotherapy and Sports Science, University College Dublin, D04V1W8 Dublin, Ireland. Hauptthemen laut MEDLINE: Heart Rate, Wearable Electronic Devices. Die Arbeit wurde bisher 31-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science Foundation Ireland, Science Foundation Ireland’s National Challenge Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The widespread use of wearable devices has enabled continuous monitoring of biometric data, including heart rate variability (HRV) and resting heart rate (RHR). However, the validity of these measurements, particularly from consumer devices like Apple Watch, remains underexplored. This study aimed to validate HRV measurements obtained from Apple Watch Series 9 and Ultra 2 against the Polar H10 chest strap paired with the Kubios HRV software, which together served as the reference standard. A prospective cohort of 39 healthy adults provided 316 HRV measurements over a 14-day period. Generalized Estimating Equations were used to assess the difference in HRV between devices, accounting for repeated measures. Apple Watch tended to underestimate HRV by an average of 8.31 ms compared to the Polar H10 (p = 0.025), with a mean absolute percentage error (MAPE) of 28.88% and a mean absolute error (MAE) of 20.46 ms. The study found no significant impact of RHR discrepancies on HRV differences (p = 0.156), with RHR showing a mean difference of −0.08 bpm, an MAPE of 5.91%, and an MAE of 3.73 bpm. Equivalence testing indicated that the HRV measurements from Apple Watch did not fall within the pre-specified equivalence margin of ±10 ms. Despite accurate RHR measurements, these findings underscore the need for improved HRV algorithms in consumer wearables and caution in interpreting HRV data for clinical or performance monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart RateWearable Electronic DevicesHumansMaleFemaleAdultProspective StudiesMonitoring, PhysiologicMiddle AgedYoung AdultSoftwareRest

Stichwörter der Autor:innen

Apple watchKubios HRVPolar H10heart rate variabilityphotoplethysmographyvaliditywearable devices

Autor:innen und Institutionen

  • School of Public Health, Physiotherapy and Sports Science, University College Dublin, D04V1W8 Dublin, Ireland.
  • Insight SFI Research Centre for Data Analytics, University College Dublin, D04V1W8 Dublin, Ireland.
  • Institute for Sport and Health, University College Dublin, D04V1W8 Dublin, Ireland.

ORCID-Profile: Ben O'Grady, Rory Lambe, Maximus Baldwin, Cailbhe Doherty

Förderung

  • Science Foundation Ireland
  • Science Foundation Ireland’s National Challenge Fund

Zitieren

APA

O'Grady, B., Lambe, R., Baldwin, M., Acheson, T., & Doherty, C. (2024). The Validity of Apple Watch Series 9 and Ultra 2 for Serial Measurements of Heart Rate Variability and Resting Heart Rate. Sensors, 24(19), 6220. https://doi.org/10.3390/s24196220

Vancouver

O'Grady B, Lambe R, Baldwin M, Acheson T, Doherty C. The Validity of Apple Watch Series 9 and Ultra 2 for Serial Measurements of Heart Rate Variability and Resting Heart Rate. Sensors. 2024;24(19):6220. doi:10.3390/s24196220

BibTeX
@article{OGrady2024,
  author = {O'Grady, Ben and Lambe, Rory and Baldwin, Maximus and Acheson, Tara and Doherty, Cailbhe},
  title = {The Validity of Apple Watch Series 9 and Ultra 2 for Serial Measurements of Heart Rate Variability and Resting Heart Rate},
  journal = {Sensors},
  year = {2024},
  volume = {24},
  number = {19},
  pages = {6220},
  doi = {10.3390/s24196220}
}
Kostenlos starten →