EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A New Measure for Quantifying Four-Limb Coordination of Human Gait Based on Mobility Sensors

Noam Galor, Gabi Zeilig, Meir Plotnik

Sensors · 2024

DOI: 10.3390/s24186105 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Noam Galor und 2 weiteren Autor:innen. Beteiligte Einrichtung: Center of Advanced Technologies in Rehabilitation, Sheba Medical Center, Ramat Gan 5266202, Israel. Hauptthemen laut MEDLINE: Gait. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Israeli Ministry of Innovation Science and Technology, Israel Science Fund, Sheba Medical Center, Second Chance award.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Coordinated movement of four limbs is a hallmark of healthy locomotion. No measures exist to quantify four-limb coordination. This study aimed to investigate temporal four-limb coordination and proposed a new metric for quantifying the inter-limb phase of rhythmic locomotion-related movements. Kinetic data of arm and leg movements generated during walking (self-selected speed) from healthy adults were used to extract the phases (φ) between all possible limb pairings. The φ series were used to calculate each pair’s Phase Coordination Index (PCI). The PCI quantifies the accuracy and consistency of generating anti-phased rhythmic movements (lower PCI values mean better coordination). We also calculated the Quadruple-PCI (Q-PCI) by combining all φ values of all limb pairs. We found a significant correlation between the PCI values of all limb pairings and the Q-PCI (pairs involving arms: Pearson’s R > 0.79, p < 0.001; leg–leg: Pearson’s R = 0.3, p < 0.01). The PCI values that involve arms (median values between 6.5% and 8.3%) were significantly higher than the leg–leg PCI (median values between 3.8% and 4.1%), and the Q-PCI (median values between 8.3% and 9.7%) was significantly higher than all other PCI values. We also found a negative correlation between the arm swing amplitude and the PCI values (Spearman’s Rho of different limb pairings ranging from −0.25 to −0.5, p < 0.05), suggesting that higher arm swing amplitude leads to better coordination. Four-limb coordination analysis is a novel method for comprehensive assessment of gait coordination, which is often compromised among persons with disabilities.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GaitHumansMaleAdultFemaleLegWalkingBiomechanical PhenomenaArmMovementLocomotionYoung Adult

Stichwörter der Autor:innen

gait analysisinter-limb coordinationlocomotionphase coordination indexrhythmic movements

Autor:innen und Institutionen

  • Center of Advanced Technologies in Rehabilitation, Sheba Medical Center, Ramat Gan 5266202, Israel.
  • Department of Neurological Rehabilitation, Sheba Medical Center, Ramat Gan 5266202, Israel.
  • Department of Physical and Rehabilitation Medicine, Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel.
  • School of Health Professions, Ono Academic College, Kiryat Ono 5545001, Israel.
  • Department of Physiology and Pharmacology, Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel.
  • Sagol School of Neuroscience, Tel Aviv University, Tel Aviv 6997801, Israel.

Förderung

  • Israeli Ministry of Innovation Science and Technology
  • Israel Science Fund
  • Sheba Medical Center, Second Chance award

Zitieren

APA

Galor, N., Zeilig, G., & Plotnik, M. (2024). A New Measure for Quantifying Four-Limb Coordination of Human Gait Based on Mobility Sensors. Sensors. https://doi.org/10.3390/s24186105

Vancouver

Galor N, Zeilig G, Plotnik M. A New Measure for Quantifying Four-Limb Coordination of Human Gait Based on Mobility Sensors. Sensors. 2024. doi:10.3390/s24186105

BibTeX
@article{Galor2024,
  author = {Galor, Noam and Zeilig, Gabi and Plotnik, Meir},
  title = {A New Measure for Quantifying Four-Limb Coordination of Human Gait Based on Mobility Sensors},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24186105}
}
Kostenlos starten →