The Determination of On-Water Rowing Stroke Kinematics Using an Undecimated Wavelet Transform of a Rowing Hull-Mounted Accelerometer Signal
Sensors · 2024
DOI: 10.3390/s24186085 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Daniel Geneau und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Exercise Science, Physical and Health Education, University of Victoria, Victoria, BC V8P 5C2, Canada. Hauptthemen laut MEDLINE: Accelerometry, Water Sports, Ships, Wavelet Analysis. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Schlaganfall
Abstract (Originalsprache)
Boat acceleration profiles can provide valuable information for coaches and practitioners to make meaningful technical interventions and monitor the determinants of success in rowing. Previous studies have used simple feature detection methods to identify key phases within individual strokes, such as drive onset, drive time, drive offset and stroke time. However, based on skill level, technique or boat class, the hull acceleration profile can differ, making robust feature detection more challenging. The current study’s purpose is to employ the undecimated wavelet transform (UWT) technique to detect individual features in the stroke acceleration profile from a single rowing hull-mounted accelerometer. In this investigation, the temporal and kinematic values obtained using the AdMosTM sensor in conjunction with the UWT processing approach were strongly correlated with the comparative measures of the Peach™ instrumented oarlock system. The measures for stroke time displayed very strong agreeability between the systems for all boat classes, with ICC values of 0.993, 0.963 and 0.954 for the W8+, W4− and W1x boats, respectively. Similarly, the drive time was also very consistent, with strong to very strong agreeability, producing ICC values of 0.937, 0.901 and 0.881 for the W8+, W4− and W1x boat classes. Further, a Bland–Altman analysis displayed little to no bias between the AdMosTM-derived and Peach™ measures, indicating that there were no systematic discrepancies between signals. This single-sensor solution could form the basis for a simple, cost-effective and accessible alternative to multi-sensor instrumented systems for the determination of sub-stroke kinematic phases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Exercise Science, Physical and Health Education, University of Victoria, Victoria, BC V8P 5C2, Canada.
- Canadian Sport Institute Pacific, Victoria, BC V9E 2C5, Canada.
ORCID-Profile: Daniel Geneau, Drew Commandeur, Ming-Chang Tsai, Marc Klimstra
Zitieren
APA
Geneau, D., Commandeur, D., Brodie, R., Tsai, M. C., Jensen, M., & Klimstra, M. (2024). The Determination of On-Water Rowing Stroke Kinematics Using an Undecimated Wavelet Transform of a Rowing Hull-Mounted Accelerometer Signal. Sensors. https://doi.org/10.3390/s24186085
Vancouver
Geneau D, Commandeur D, Brodie R, Tsai MC, Jensen M, Klimstra M. The Determination of On-Water Rowing Stroke Kinematics Using an Undecimated Wavelet Transform of a Rowing Hull-Mounted Accelerometer Signal. Sensors. 2024. doi:10.3390/s24186085
BibTeX
@article{Geneau2024,
author = {Geneau, Daniel and Commandeur, Drew and Brodie, Ryan and Tsai, Ming-Chang and Jensen, Matt and Klimstra, Marc},
title = {The Determination of On-Water Rowing Stroke Kinematics Using an Undecimated Wavelet Transform of a Rowing Hull-Mounted Accelerometer Signal},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24186085}
}
EUVIMED