Research on the Motion Control Strategy of a Lower-Limb Exoskeleton Rehabilitation Robot Using the Twin Delayed Deep Deterministic Policy Gradient Algorithm
Sensors · 2024
DOI: 10.3390/s24186014 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Yifeng Guo und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical Engineering, Chengdu University, Chengdu 610106, China. Hauptthemen laut MEDLINE: Algorithms, Exoskeleton Device, Lower Extremity, Robotics. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Sichuan Provincial Regional Innovation Cooperation Project, the Sichuan Natural Science Foundation, Project for Enhancing Young and Middle aged Teacher's Research Basis Ability in Colleges of Guangxi.
Abstract (Originalsprache)
The motion control system of a lower-limb exoskeleton rehabilitation robot (LLERR) is designed to assist patients in lower-limb rehabilitation exercises. This research designed a motion controller for an LLERR-based on the Twin Delayed Deep Deterministic policy gradient (TD3) algorithm to control the lower-limb exoskeleton for gait training in a staircase environment. Commencing with the establishment of a mathematical model of the LLERR, the dynamics during its movement are systematically described. The TD3 algorithm is employed to plan the motion trajectory of the LLERR’s right-foot sole, and the target motion curve of the hip (knee) joint is deduced inversely to ensure adherence to human physiological principles during motion execution. The control strategy of the TD3 algorithm ensures that the movement of each joint of the LLERR is consistent with the target motion trajectory. The experimental results indicate that the trajectory tracking errors of the hip (knee) joints are all within 5°, confirming that the LLERR successfully assists patient in completing lower-limb rehabilitation training in a staircase environment. The primary contribution of this study is to propose a non-linear control strategy tailored for the staircase environment, enabling the planning and control of the lower-limb joint motions facilitated by the LLERR.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Mechanical Engineering, Chengdu University, Chengdu 610106, China.
- School of Artificial Intelligence, Hezhou University, Hezhou 542899, China.
Förderung
- the Sichuan Provincial Regional Innovation Cooperation Project
- the Sichuan Natural Science Foundation
- Project for Enhancing Young and Middle aged Teacher's Research Basis Ability in Colleges of Guangxi
- the Chengdu City Technology Innovation R&D Project
- the Sichuan College Students' Innovation and Entrepreneurship Program
- Sichuan Provincial Regional Innovation Cooperation Project
- Sichuan Natural Science Foundation
- Project for Enhancing Young and Middle aged Teacher’s Research Basis Ability in Colleges of Guangxi
Zitieren
APA
Guo, Y., He, M., Tong, X., Zhang, M., & Huang, L. (2024). Research on the Motion Control Strategy of a Lower-Limb Exoskeleton Rehabilitation Robot Using the Twin Delayed Deep Deterministic Policy Gradient Algorithm. Sensors. https://doi.org/10.3390/s24186014
Vancouver
Guo Y, He M, Tong X, Zhang M, Huang L. Research on the Motion Control Strategy of a Lower-Limb Exoskeleton Rehabilitation Robot Using the Twin Delayed Deep Deterministic Policy Gradient Algorithm. Sensors. 2024. doi:10.3390/s24186014
BibTeX
@article{Guo2024,
author = {Guo, Yifeng and He, Min and Tong, Xubin and Zhang, Min and Huang, Limin},
title = {Research on the Motion Control Strategy of a Lower-Limb Exoskeleton Rehabilitation Robot Using the Twin Delayed Deep Deterministic Policy Gradient Algorithm},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24186014}
}
EUVIMED