EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Development of Surface EMG for Gait Analysis and Rehabilitation of Hemiparetic Patients

Didier Pradon, Li Tong, Christos Chalitsios iD, Nicolas Roche

Sensors · 2024

DOI: 10.3390/s24185954 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Didier Pradon und 3 weiteren Autor:innen. Beteiligte Einrichtung: Pôle Parasport University Hospital Raymond Poincaré, APHP, 92380 Garches, France. Hauptthemen laut MEDLINE: Electromyography, Paresis, Gait Analysis. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The quantification of electromyographic activity using surface electrodes is invaluable for understanding gait disorders in patients with central nervous system lesions. We propose to evaluate a commercially available low-cost system compared to a reference system in participants with stroke-related movement disorders in functional situations.

Methods

Three hemiparetic participants performed three functional tasks: two treadmill walks at different speeds and a sit-to-stand test. The vastus lateralis and gastrocnemius medialis muscles were equipped with two EMG sensors. The comparison between the two EMG systems was based on 883 identified cycles. Spearman’s correlation coefficients (SCs), linear correlation coefficients (LCCs), and cross-correlation coefficients (CCCs) were calculated.

Results

The main results indicate good to very good similarity of the EMG signals collected from the two tested sEMG systems. In the comfortable-walking condition, an SC of 0.894 ± 0.091 and an LCC of 0.909 ± 0.094 were noted. In the fast-walking condition, an SC of 0.918 ± 0.064 and an LCC of 0.935 ± 0.056 were observed. For the 1 min sit-to-stand test, an SC of 0.880 ± 0.058 and an LCC of 0.881 ± 0.065 were noted.

Conclusions

This study demonstrates good to very good similarity between the two sEMG systems, enabling the analysis of muscle activity during functional tasks.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectromyographyParesisGait AnalysisHumansMaleWalkingMiddle AgedFemaleMuscle, SkeletalGaitStroke RehabilitationStrokeAdult

Stichwörter der Autor:innen

EMGgaitstrokevalidation

Autor:innen und Institutionen

  • Pôle Parasport University Hospital Raymond Poincaré, APHP, 92380 Garches, France.
  • U1179 Endicap, Versailles Saint Quentin University, 78000 Versailles, France.
  • Kinvent, 34000 Montpellier, France.
  • Biomechanics Laboratory, Aristotle University of Thessaloniki, 57001 Thessaloniki, Greece.
  • Service d'Explorations Fonctionnelles, University Hospital Raymond Poincaré, APHP, 92380 Garches, France.

ORCID-Profile: Christos Chalitsios

Zitieren

APA

Pradon, D., Tong, L., Chalitsios, C., & Roche, N. (2024). Development of Surface EMG for Gait Analysis and Rehabilitation of Hemiparetic Patients. Sensors. https://doi.org/10.3390/s24185954

Vancouver

Pradon D, Tong L, Chalitsios C, Roche N. Development of Surface EMG for Gait Analysis and Rehabilitation of Hemiparetic Patients. Sensors. 2024. doi:10.3390/s24185954

BibTeX
@article{Pradon2024,
  author = {Pradon, Didier and Tong, Li and Chalitsios, Christos and Roche, Nicolas},
  title = {Development of Surface EMG for Gait Analysis and Rehabilitation of Hemiparetic Patients},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24185954}
}
Kostenlos starten →