Looping Flexible Fluoropolymer Microcapillary Film Extends Analysis Times for Vertical Microfluidic Blood Testing
Sensors · 2024
DOI: 10.3390/s24185870 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Rüya Meltem Sarıyer und 5 weiteren Autor:innen. Beteiligte Einrichtung: Reading School of Pharmacy, University of Reading, Whiteknights, Reading RG6 6UB, UK. Hauptthemen laut MEDLINE: Thrombin, Lab-On-A-Chip Devices. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIHR, Turkish Ministry of National Education.
Abstract (Originalsprache)
The microfluidic measurement of capillary flow can be used to evaluate the response of biological samples to stimulation, where distance and velocity are altered. Melt-extruded multi-bored microfluidic capillaries allow for high-throughput testing with low device cost, but simple devices may limit control over sample flow when compared to the more complex “lab-on-a-chip” devices produced using advanced microfluidic fabrication methods. Previously, we measured the dynamics of global haemostasis stimulated by thrombin by dipping straight vertical microcapillaries into blood, but only the most rapid response could be monitored, as flow slowed significantly within 30 s. Here, we show an innovative method to extend both the stimulation process and flow measurement time without increasing the cost of the device by adding simple loops to the flexible extruded device. The loops enable longer time-scale measurements by increasing resistance to flow, thereby reducing the dependence on high stimulus concentrations for rapid reactions. The instantaneous velocity and equilibrium heights of straight and looped vertical microcapillary films were assessed with water, plasma and whole blood, showing that the loops create additional frictional resistances, reduce flow velocity and prolong residence times for increased time scales of the stimulation process. A modified pressure balance model was used to capture flow dynamics with the added loop. Looped devices loaded with thrombin and collagen showed an improved detection of blood stimulation responses even with lower stimulus concentrations, compared to straight vertical capillaries. Thrombin-activated blood samples in straight capillaries provided a maximum measurement zone of only 4 mm, while the looped design significantly increased this to 11 mm for much longer time scale measurements. Our results suggest that extending stimulation times can be achieved without complex microfluidic fabrication methods, potentially improving concentration–response blood stimulation assays, and may enhance the accuracy and reliability. We conclude adding a loop to low-cost extruded microfluidic devices may bring microfluidic devices closer to delivering on their promise of widespread, decentralized low-cost evaluation of blood response to stimulation in both research and clinical settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Reading School of Pharmacy, University of Reading, Whiteknights, Reading RG6 6UB, UK.
- Department of Surgery, Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02129, USA.
- Department of Chemical Engineering and Centre for Bioengineering and Biomedical Technologies (CBio), University of Bath, Bath BA2 7AY, UK.
- Reading School of Biological Sciences, University of Reading, Whiteknights, Reading RG6 6AH, UK.
- School of Electronics and Computer Science, University of Southampton, Highfield, Southampton SO17 1BJ, UK.
- Institute for Life Sciences, University of Southampton, Highfield, Southampton SO17 1BJ, UK.
ORCID-Profile: Rüya Meltem Sarıyer, Kirandeep K Gill, Sarah H Needs, Nuno M Reis, Chris I Jones, Alexander Daniel Edwards
Förderung
- NIHR
- Turkish Ministry of National Education
Zitieren
APA
Sarıyer, R. M., Gill, K. K., Needs, S. H., Reis, N. M., Jones, C. I., & Edwards, A. D. (2024). Looping Flexible Fluoropolymer Microcapillary Film Extends Analysis Times for Vertical Microfluidic Blood Testing. Sensors. https://doi.org/10.3390/s24185870
Vancouver
Sarıyer RM, Gill KK, Needs SH, Reis NM, Jones CI, Edwards AD. Looping Flexible Fluoropolymer Microcapillary Film Extends Analysis Times for Vertical Microfluidic Blood Testing. Sensors. 2024. doi:10.3390/s24185870
BibTeX
@article{Saryer2024,
author = {Sarıyer, Rüya Meltem and Gill, Kirandeep K and Needs, Sarah H and Reis, Nuno M and Jones, Chris I and Edwards, Alexander Daniel},
title = {Looping Flexible Fluoropolymer Microcapillary Film Extends Analysis Times for Vertical Microfluidic Blood Testing},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24185870}
}
EUVIMED