EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Feasibility Study on the Use of NO2 and PM2.5 Sensors for Exposure Assessment and Indoor Source Apportionment at Fixed Locations

Miriam Chacón-Mateos iD, Erika Remy iD, Uta Liebers iD, Frank Heimann, Christian Witt, Ulrich Vogt

Sensors · 05.09.2024 · 24 (17) · 5767

DOI: 10.3390/s24175767 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 05.09.2024. Verfasst von Miriam Chacón-Mateos und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Flue Gas Cleaning and Air Quality Control, University of Stuttgart, 70569 Stuttgart, Germany. Hauptthemen laut MEDLINE: Particulate Matter, Air Pollution, Indoor, Environmental Monitoring, Nitrogen Dioxide. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry for Social Affairs and Integration Baden-Württemberg.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Recent advances in sensor technology for air pollution monitoring open new possibilities in the field of environmental epidemiology. The low spatial resolution of fixed outdoor measurement stations and modelling uncertainties currently limit the understanding of personal exposure. In this context, air quality sensor systems (AQSSs) offer significant potential to enhance personal exposure assessment. A pilot study was conducted to investigate the feasibility of the NO2 sensor model B43F and the particulate matter (PM) sensor model OPC-R1, both from Alphasense (UK), for use in epidemiological studies. Seven patients with chronic obstructive pulmonary disease (COPD) or asthma had built-for-purpose sensor systems placed inside and outside of their homes at fixed locations for one month. Participants documented their indoor activities, presence in the house, window status, and symptom severity and performed a peak expiratory flow test. The potential inhaled doses of PM2.5 and NO2 were calculated using different data sources such as outdoor data from air quality monitoring stations, indoor data from AQSSs, and generic inhalation rates (IR) or activity-specific IR. Moreover, the relation between indoor and outdoor air quality obtained with AQSSs, an indoor source apportionment study, and an evaluation of the suitability of the AQSS data for studying the relationship between air quality and health were investigated. The results highlight the value of the sensor data and the importance of monitoring indoor air quality and activity patterns to avoid exposure misclassification. The use of AQSSs at fixed locations shows promise for larger-scale and/or long-term epidemiological studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Particulate MatterAir Pollution, IndoorEnvironmental MonitoringNitrogen DioxideFeasibility StudiesHumansMaleAsthmaPulmonary Disease, Chronic ObstructiveAir PollutantsFemaleMiddle AgedAgedEnvironmental ExposurePilot Projects

Stichwörter der Autor:innen

I/O ratioair qualityexposure assessmentindoor airlow-cost sensorssource apportionment

Substanzen

Particulate MatterNitrogen DioxideAir Pollutants

Autor:innen und Institutionen

  • Department of Flue Gas Cleaning and Air Quality Control, University of Stuttgart, 70569 Stuttgart, Germany.
  • Institute of Physics and Meteorology, University of Hohenheim, 70599 Stuttgart, Germany.
  • Institute of Physiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, 10117 Berlin, Germany.
  • Department of Pneumology, Evangelische Lungenklinik Berlin Buch, 13125 Berlin, Germany.
  • Ambulante Pneumologie mit Allergie Zentrum, 70178 Stuttgart, Germany.

ORCID-Profile: Miriam Chacón-Mateos, Erika Remy, Uta Liebers

Förderung

  • Ministry for Social Affairs and Integration Baden-Württemberg

Zitieren

APA

Chacón-Mateos, M., Remy, E., Liebers, U., Heimann, F., Witt, C., & Vogt, U. (2024). Feasibility Study on the Use of NO2 and PM2.5 Sensors for Exposure Assessment and Indoor Source Apportionment at Fixed Locations. Sensors, 24(17), 5767. https://doi.org/10.3390/s24175767

Vancouver

Chacón-Mateos M, Remy E, Liebers U, Heimann F, Witt C, Vogt U. Feasibility Study on the Use of NO2 and PM2.5 Sensors for Exposure Assessment and Indoor Source Apportionment at Fixed Locations. Sensors. 2024;24(17):5767. doi:10.3390/s24175767

BibTeX
@article{ChacnMateos2024,
  author = {Chacón-Mateos, Miriam and Remy, Erika and Liebers, Uta and Heimann, Frank and Witt, Christian and Vogt, Ulrich},
  title = {Feasibility Study on the Use of NO2 and PM2.5 Sensors for Exposure Assessment and Indoor Source Apportionment at Fixed Locations},
  journal = {Sensors},
  year = {2024},
  volume = {24},
  number = {17},
  pages = {5767},
  doi = {10.3390/s24175767}
}
Kostenlos starten →