One-Channel Wearable Mental Stress State Monitoring System
Sensors · 20.08.2024 · 24 (16) · 5373
DOI: 10.3390/s24165373 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 20.08.2024. Verfasst von Lamis Abdul Kader und 3 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Engineering Graduate Program, College of Engineering, American University of Sharjah, Sharjah P.O. Box 26666, United Arab Emirates. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Electroencephalography, Stress, Psychological, Galvanic Skin Response. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: American University of Sharjah.
Abstract (Originalsprache)
Assessments of stress can be performed using physiological signals, such as electroencephalograms (EEGs) and galvanic skin response (GSR). Commercialized systems that are used to detect stress with EEGs require a controlled environment with many channels, which prohibits their daily use. Fortunately, there is a rise in the utilization of wearable devices for stress monitoring, offering more flexibility. In this paper, we developed a wearable monitoring system that integrates both EEGs and GSR. The novelty of our proposed device is that it only requires one channel to acquire both physiological signals. Through sensor fusion, we achieved an improved accuracy, lower cost, and improved ease of use. We tested the proposed system experimentally on twenty human subjects. We estimated the power spectrum of the EEG signals and utilized five machine learning classifiers to differentiate between two levels of mental stress. Furthermore, we investigated the optimum electrode location on the scalp when using only one channel. Our results demonstrate the system’s capability to classify two levels of mental stress with a maximum accuracy of 70.3% when using EEGs alone and 84.6% when using fused EEG and GSR data. This paper shows that stress detection is reliable using only one channel on the prefrontal and ventrolateral prefrontal regions of the brain.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Biomedical Engineering Graduate Program, College of Engineering, American University of Sharjah, Sharjah P.O. Box 26666, United Arab Emirates.
- Department of Rehabilitation and Movement Sciences, Rutgers University, Newark, NJ 07107, USA.
- Department of Electrical Engineering, College of Engineering, American University of Sharjah, Sharjah P.O. Box 26666, United Arab Emirates.
ORCID-Profile: Fares Al-Shargie, Usman Tariq, Hasan Al-Nashash
Förderung
- American University of Sharjah
Zitieren
APA
Abdul Kader, L., Al-Shargie, F., Tariq, U., & Al-Nashash, H. (2024). One-Channel Wearable Mental Stress State Monitoring System. Sensors, 24(16), 5373. https://doi.org/10.3390/s24165373
Vancouver
Abdul Kader L, Al-Shargie F, Tariq U, Al-Nashash H. One-Channel Wearable Mental Stress State Monitoring System. Sensors. 2024;24(16):5373. doi:10.3390/s24165373
BibTeX
@article{AbdulKader2024,
author = {Abdul Kader, Lamis and Al-Shargie, Fares and Tariq, Usman and Al-Nashash, Hasan},
title = {One-Channel Wearable Mental Stress State Monitoring System},
journal = {Sensors},
year = {2024},
volume = {24},
number = {16},
pages = {5373},
doi = {10.3390/s24165373}
}
EUVIMED