50 Hz Temporal Magnetic Field Monitoring from High-Voltage Power Lines: Sensor Design and Experimental Validation
Sensors · 17.08.2024 · 24 (16) · 5325
DOI: 10.3390/s24165325 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 17.08.2024. Verfasst von Kenneth Deprez und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Information Technology, Ghent University/imec WAVES, 9052 Ghent, Belgium. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The department of Environment & Spatial Development Flanders, The Department of Environment & Spatial Development Flanders.
Abstract (Originalsprache)
A low-cost, tri-axial 50 Hz magnetic field monitoring sensor was designed, calibrated and verified. The sensor was designed using off-the-shelf components and commercially available coils. It can measure 50 Hz magnetic fields originating from high-voltage power lines from 0.08 µT to 364 µT, divided into two measurement ranges. The sensor was calibrated both on-board and in-lab. The on-board calibration takes the circuit attenuation, noise and parasitic components into account. In the in-lab calibration, the output of the developed sensor is compared to the benchmark, a narrowband EHP-50. The sensor was then verified in situ under high-voltage power lines at two independent measurement locations. The measured field values during this validation were between 0.10 µT and 13.43 µT, which is in agreement with other reported measurement values under high-voltage power lines in literature. The results were compared to the benchmark, for which average deviations of 6.2% and 1.4% were found, at the two independent measurement locations. Furthermore, fields up to 113.3 µT were measured in a power distribution sub-station to ensure that both measurement ranges were verified. Our network, four active sensors in the field, had high uptimes of 96%, 82%, 81% and, 95% during a minimum 3-month interval. In total, over 6 million samples were gathered with field values that ranged from 0.08 µT to 45.48 µT. This suggests that the proposed solution can be used for this monitoring, although more extensive long-term testing with more sensors is required to confirm the uptime under multiple circumstances.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Information Technology, Ghent University/imec WAVES, 9052 Ghent, Belgium.
- Department of Environment & Spatial Development, Flemish Planning Bureau for the Environment and Spatial Development, 1000 Brussels, Belgium.
ORCID-Profile: Kenneth Deprez, Tom Van de Steene, Leen Verloock, Emmeric Tanghe, Liesbeth Gommé, David Plets, Wout Joseph
Förderung
- The department of Environment & Spatial Development Flanders
- The Department of Environment & Spatial Development Flanders
Zitieren
APA
Deprez, K., Van de Steene, T., Verloock, L., Tanghe, E., Gommé, L., Verlaek, M., Goethals, M., van Campenhout, K., Plets, D., & Joseph, W. (2024). 50 Hz Temporal Magnetic Field Monitoring from High-Voltage Power Lines: Sensor Design and Experimental Validation. Sensors, 24(16), 5325. https://doi.org/10.3390/s24165325
Vancouver
Deprez K, Van de Steene T, Verloock L, Tanghe E, Gommé L, Verlaek M, et al. 50 Hz Temporal Magnetic Field Monitoring from High-Voltage Power Lines: Sensor Design and Experimental Validation. Sensors. 2024;24(16):5325. doi:10.3390/s24165325
BibTeX
@article{Deprez2024,
author = {Deprez, Kenneth and Van de Steene, Tom and Verloock, Leen and Tanghe, Emmeric and Gommé, Liesbeth and Verlaek, Mart and Goethals, Michel and van Campenhout, Karen and Plets, David and Joseph, Wout},
title = {50 Hz Temporal Magnetic Field Monitoring from High-Voltage Power Lines: Sensor Design and Experimental Validation},
journal = {Sensors},
year = {2024},
volume = {24},
number = {16},
pages = {5325},
doi = {10.3390/s24165325}
}
EUVIMED