Defect Detection of GFRP Composites through Long Pulse Thermography Using an Uncooled Microbolometer Infrared Camera
Sensors · 12.08.2024 · 24 (16) · 5225
DOI: 10.3390/s24165225 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 12.08.2024. Verfasst von Murniwati Anwar und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, University Kuala Lumpur Malaysia France Institute (UniKL-MFI), Bandar Baru Bangi 43650, Malaysia. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 72 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Yayasan Universiti Teknologi PETRONAS.
Abstract (Originalsprache)
The detection of impact and depth defects in Glass Fiber Reinforced Polymer (GFRP) composites has been extensively studied to develop effective, reliable, and cost-efficient assessment methods through various Non-Destructive Testing (NDT) techniques. Challenges in detecting these defects arise from varying responses based on the geometrical shape, thickness, and defect types. Long Pulse Thermography (LPT), utilizing an uncooled microbolometer and a low-resolution infrared (IR) camera, presents a promising solution for detecting both depth and impact defects in GFRP materials with a single setup and minimal tools at an economical cost. Despite its potential, the application of LPT has been limited due to susceptibility to noise from environmental radiation and reflections, leading to blurry images. This study focuses on optimizing LPT parameters to achieve accurate defect detection. Specifically, we investigated 11 flat-bottom hole (FBH) depth defects and impact defects ranging from 8 J to 15 J in GFRP materials. The key parameters examined include the environmental temperature, background reflection, background color reflection, and surface emissivity. Additionally, we employed image processing techniques to classify composite defects and automatically highlight defective areas. The Tanimoto Criterion (TC) was used to evaluate the accuracy of LPT both for raw images and post-processed images. The results demonstrate that through parameter optimization, the depth defects in GFRP materials were successfully detected. The TC success rate reached 0.91 for detecting FBH depth defects in raw images, which improved significantly after post-processing using Canny edge detection and Hough circle detection algorithms. This study underscores the potential of optimized LPT as a cost-effective and reliable method for detecting defects in GFRP composites.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanical Engineering, University Kuala Lumpur Malaysia France Institute (UniKL-MFI), Bandar Baru Bangi 43650, Malaysia.
- Department of Aerospace Engineering, Faculty of Engineering, Universiti Putra Malaysia, Serdang 43400, Malaysia.
- Department of Mechanical Engineering, Universiti Teknologi Petronas, Seri Iskandar 32610, Malaysia.
- LANL-JBNU Engineering Institute-Korea, Jeonbuk National University, 567 Baekje-daero, Deokjin-gu, Jeonju-si 54896, Jeollabuk-do, Republic of Korea.
ORCID-Profile: Murniwati Anwar, Faizal Mustapha, Mohd Na'im Abdullah, Azlan Ahmad, Siti Zubaidah Mat Daud
Förderung
- Yayasan Universiti Teknologi PETRONAS
Zitieren
APA
Anwar, M., Mustapha, F., Abdullah, M. N., Mustapha, M., Sallih, N., Ahmad, A., & Mat Daud, S. Z. (2024). Defect Detection of GFRP Composites through Long Pulse Thermography Using an Uncooled Microbolometer Infrared Camera. Sensors, 24(16), 5225. https://doi.org/10.3390/s24165225
Vancouver
Anwar M, Mustapha F, Abdullah MN, Mustapha M, Sallih N, Ahmad A, et al. Defect Detection of GFRP Composites through Long Pulse Thermography Using an Uncooled Microbolometer Infrared Camera. Sensors. 2024;24(16):5225. doi:10.3390/s24165225
BibTeX
@article{Anwar2024,
author = {Anwar, Murniwati and Mustapha, Faizal and Abdullah, Mohd Na'im and Mustapha, Mazli and Sallih, Nabihah and Ahmad, Azlan and Mat Daud, Siti Zubaidah},
title = {Defect Detection of GFRP Composites through Long Pulse Thermography Using an Uncooled Microbolometer Infrared Camera},
journal = {Sensors},
year = {2024},
volume = {24},
number = {16},
pages = {5225},
doi = {10.3390/s24165225}
}
EUVIMED