Reliable Stenosis Detection Based on Thrill Waveform Analysis Using Non-Contact Arteriovenous Fistula Imaging
Sensors · 05.08.2024 · 24 (15) · 5068
DOI: 10.3390/s24155068 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 05.08.2024. Verfasst von Rumi Iwai und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dental Anesthesiology, Kyushu University Hospital, Fukuoka 819-0395, Japan. Hauptthemen laut MEDLINE: Renal Dialysis. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science, JST Moonshot R&D, JSPS KAKENHI.
Abstract (Originalsprache)
Hemodialysis therapy is an extracorporeal circulation treatment that serves as a substitute for renal function. In Japan, patients receive this efficient four-hour treatment, three times per week, allowing them to maintain a social life nearly equivalent to that of healthy individuals. Before the treatment, two punctures are performed to establish extracorporeal circulation, and a high blood flow rate is essential to ensure efficient therapy. Specialized blood vessels created through arteriovenous fistula (AVF) surgery are utilized to achieve high blood flow rates. Although the AVF allows safe and efficient dialysis treatment, AVF stenosis leads to a serious problem in dialysis. To early detect this abnormal blood flow, auscultation and palpation methods are widely used in hospitals. However, these methods can only provide qualitative judgment of the AVF condition, so the results cannot be shared among other doctors and staff. Additionally, since the conventional methods require contact with the skin, some issues require consideration regarding infection and low reproducibility. In our previous study, we proposed an alternative method for auscultation using non-contact optical imaging technology. This study aims to construct a reliable AVF stenosis detection method using Thrill waveform analysis based on the developed non-contact device to solve the problem with the contact palpation method. This paper demonstrates the performance validation of the non-contact imaging in the normal AVF group (206 total data, 75 patients, mean age: 69.1 years) and in the treatable stenosis group (107 total data, 17 patients, mean age: 70.1 years). The experimental results of the Mann–Whitney U test showed a significant difference (p=0.0002) between the normal and abnormal groups, which indicated the effectiveness of the proposed method as a new possible alternative to palpation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Dental Anesthesiology, Kyushu University Hospital, Fukuoka 819-0395, Japan.
- Department of Clinical Engineering, Faculty of Health Care, Jikei University of Health Care Sciences, Osaka 532-0003, Japan.
- Graduate School of Engineering, Osaka Metropolitan University, Osaka 558-8585, Japan.
- Graduate School of Engineering, Nagoya Institute of Technology, Nagoya 466-8555, Japan.
- Department of Clinical Engineering, Shikoku Central Hospital of the Mutual Aid Association of Public School Teachers, Ehime 799-0193, Japan.
- Department of Dental Anesthesiology, Faculty of Dental Science, Kyushu University, Fukuoka 812-8582, Japan.
ORCID-Profile: Rumi Iwai, Takunori Shimazaki, Jaakko Hyry, Yoshifumi Kawakubo, Takeshi Yokoyama, Daisuke Anzai
Förderung
- Japan Society for the Promotion of Science
- JST Moonshot R&D
- JSPS KAKENHI
- JST Moonshot R&D
Zitieren
APA
Iwai, R., Shimazaki, T., Hyry, J., Kawakubo, Y., Fukuhara, M., Aono, H., Ata, S., Yokoyama, T., & Anzai, D. (2024). Reliable Stenosis Detection Based on Thrill Waveform Analysis Using Non-Contact Arteriovenous Fistula Imaging. Sensors, 24(15), 5068. https://doi.org/10.3390/s24155068
Vancouver
Iwai R, Shimazaki T, Hyry J, Kawakubo Y, Fukuhara M, Aono H, et al. Reliable Stenosis Detection Based on Thrill Waveform Analysis Using Non-Contact Arteriovenous Fistula Imaging. Sensors. 2024;24(15):5068. doi:10.3390/s24155068
BibTeX
@article{Iwai2024,
author = {Iwai, Rumi and Shimazaki, Takunori and Hyry, Jaakko and Kawakubo, Yoshifumi and Fukuhara, Masashi and Aono, Hiroki and Ata, Shingo and Yokoyama, Takeshi and Anzai, Daisuke},
title = {Reliable Stenosis Detection Based on Thrill Waveform Analysis Using Non-Contact Arteriovenous Fistula Imaging},
journal = {Sensors},
year = {2024},
volume = {24},
number = {15},
pages = {5068},
doi = {10.3390/s24155068}
}
EUVIMED