Between-Session Reliability of Field-Based Assessments of Isometric Neck Strength
Sensors · 02.08.2024 · 24 (15) · 5015
DOI: 10.3390/s24155015 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 02.08.2024. Verfasst von Samuel W Oxford und 2 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Physical Activity Sport and Exercise Science, Coventry University, Priory Street, Coventry CV15FB, UK. Hauptthemen laut MEDLINE: Isometric Contraction, Muscle Strength. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The reliability of the fixed-frame dynamometer for measuring isometric neck strength is established, but with limited field-based applications. This study aimed to establish the inter- and intra-session reliability of the peak force for neck flexors, extensors, and side flexors using the VALD ForceFrame and DynaMo and the force–time characteristics in the quadruped position (ForceFrame). Twenty-seven recreationally active males performed three repetitions of isometric neck flexion, extension, and side flexion over two sessions in random order using the VALD ForceFrame and DynaMo. Both devices demonstrated acceptable reliability, with the Forceframe ICC > 0.8 and CV% < 13.8% and the DynaMo ICC > 0.76 and CV% < 13.8%. No systematic or proportional differences were found using the Passing–Bablock procedure, and Bland–Altman analysis confirmed agreement across measures. Reliability was shown for right-side (ICC > 0.76) and left-side (ICC > 0.79) flexion and flexion (ICC > 0.75) across 50, 100, 150, and 200 ms. Statistical parametric mapping indicated no differences in ForceFrame-generated isometric force–time curves between sessions, though the CV was highest in the force development phase. The findings suggest that both tools can reliably assess neck strength, supporting their use in sports and clinical settings. However, assessment methods are not interchangeable, emphasising the need for standardised neck strength assessment approaches.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Centre for Physical Activity Sport and Exercise Science, Coventry University, Priory Street, Coventry CV15FB, UK.
- College of Life Sciences, Faculty of Health, Education and Life Sciences, Birmingham City University, Edgbaston, Birmingham B153TN, UK.
ORCID-Profile: Samuel W Oxford, Neil D Clarke, Jason Tallis
Zitieren
APA
Oxford, S. W., Clarke, N. D., & Tallis, J. (2024). Between-Session Reliability of Field-Based Assessments of Isometric Neck Strength. Sensors, 24(15), 5015. https://doi.org/10.3390/s24155015
Vancouver
Oxford SW, Clarke ND, Tallis J. Between-Session Reliability of Field-Based Assessments of Isometric Neck Strength. Sensors. 2024;24(15):5015. doi:10.3390/s24155015
BibTeX
@article{Oxford2024,
author = {Oxford, Samuel W and Clarke, Neil D and Tallis, Jason},
title = {Between-Session Reliability of Field-Based Assessments of Isometric Neck Strength},
journal = {Sensors},
year = {2024},
volume = {24},
number = {15},
pages = {5015},
doi = {10.3390/s24155015}
}
EUVIMED