Validation of the Kinematic Assessment Protocol Used in the Technology-Supported Neurorehabilitation System, Rehabilitation Technologies for Hand and Arm (R3THA™), in Children and Teenagers with Cerebral Palsy
Sensors · 2024
DOI: 10.3390/s24155013 ↗Kurz gefasst
Studienprotokoll in der Zeitschrift Sensors, 2024. Verfasst von Qinyin Qiu und 5 weiteren Autor:innen. Beteiligte Einrichtung: NeuroTechR3, Inc., 211 Warren Street, Newark, NJ 07103, USA. Hauptthemen laut MEDLINE: Cerebral Palsy, Hand, Arm. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NICHD NIH HHS.
Themen: Kinderkrankenpflege
Abstract (Originalsprache)
This study evaluates the R3THA™ assessment protocol (R3THA-AP™), a technology-supported testing module for personalized rehabilitation in children with cerebral palsy (CP). It focuses on the reliability and validity of the R3THA-AP in assessing hand and arm function, by comparing kinematic assessments with standard clinical assessments. Conducted during a 4-week summer camp, the study assessed the functional and impairment levels of children with CP aged 3–18. The findings suggest that R3THA is more reliable for children aged 8 and older, indicating that age significantly influences the protocol’s effectiveness. The results also showed that the R3THA-AP’s kinematic measurements of hand and wrist movements are positively correlated with the Box and Blocks Test Index (BBTI), reflecting hand function and dexterity. Additionally, the R3THA-AP’s accuracy metrics for hand and wrist activities align with the Melbourne Assessment 2’s Range of Motion (MA2-ROM) scores, suggesting a meaningful relationship between R3THA-AP data and clinical assessments of motor skills. However, no significant correlations were observed between the R3THA-AP and MA2’s accuracy and dexterity measurements, indicating areas for further research. These findings validate the R3THA-AP’s utility in assessing motor abilities in CP patients, supporting its integration into clinical practice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- NeuroTechR3, Inc., 211 Warren Street, Newark, NJ 07103, USA.
- Rutgers Biomedical and Health Sciences, Rutgers University, 65 Bergen St, Newark, NJ 07107, USA.
- Department of Biomedical Engineering, New Jersey Institute of Technology, 323 Dr Martin Luther King Jr Blvd, Newark, NJ 07102, USA.
ORCID-Profile: Ashley J Mont, Mee Eriksson
Förderung
- NICHD NIH HHS
Zitieren
APA
Qiu, Q., Mont, A. J., Gross, A., Fluet, G., Adamovich, S., & Eriksson, M. (2024). Validation of the Kinematic Assessment Protocol Used in the Technology-Supported Neurorehabilitation System, Rehabilitation Technologies for Hand and Arm (R3THA™), in Children and Teenagers with Cerebral Palsy. Sensors. https://doi.org/10.3390/s24155013
Vancouver
Qiu Q, Mont AJ, Gross A, Fluet G, Adamovich S, Eriksson M. Validation of the Kinematic Assessment Protocol Used in the Technology-Supported Neurorehabilitation System, Rehabilitation Technologies for Hand and Arm (R3THA™), in Children and Teenagers with Cerebral Palsy. Sensors. 2024. doi:10.3390/s24155013
BibTeX
@article{Qiu2024,
author = {Qiu, Qinyin and Mont, Ashley J and Gross, Amanda and Fluet, Gerard and Adamovich, Sergei and Eriksson, Mee},
title = {Validation of the Kinematic Assessment Protocol Used in the Technology-Supported Neurorehabilitation System, Rehabilitation Technologies for Hand and Arm (R3THA™), in Children and Teenagers with Cerebral Palsy},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24155013}
}
EUVIMED