Evaluation of the Reliability of the CCM-300 Chlorophyll Content Meter in Measuring Chlorophyll Content for Various Plant Functional Types
Sensors · 2024
DOI: 10.3390/s24154784 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Joelie M Van Beek und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Forest and Wildlife Ecology, University of Wisconsin-Madison, 1630 Linden Drive, Madison, WI 53706, USA. Hauptthemen laut MEDLINE: Chlorophyll, Plant Leaves. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science Foundation, NSF ASCEND Biology Integration Institute (BII), NSF Macrosystems Biology and NEON-Enabled Science (MSB-NES).
Abstract (Originalsprache)
Chlorophyll fluorescence is a well-established method to estimate chlorophyll content in leaves. A popular fluorescence-based meter, the Opti-Sciences CCM-300 Chlorophyll Content Meter (CCM-300), utilizes the fluorescence ratio F735/F700 and equations derived from experiments using broadleaf species to provide a direct, rapid estimate of chlorophyll content used for many applications. We sought to quantify the performance of the CCM-300 relative to more intensive methods, both across plant functional types and years of use. We linked CCM-300 measurements of broadleaf, conifer, and graminoid samples in 2018 and 2019 to high-performance liquid chromatography (HPLC) and/or spectrophotometric (Spec) analysis of the same leaves. We observed a significant difference between the CCM-300 and HPLC/Spec, but not between HPLC and Spec. In comparison to HPLC, the CCM-300 performed better for broadleaves (r = 0.55, RMSE = 154.76) than conifers (r = 0.52, RMSE = 171.16) and graminoids (r = 0.32, RMSE = 127.12). We observed a slight deterioration in meter performance between years, potentially due to meter calibration. Our results show that the CCM-300 is reliable to demonstrate coarse variations in chlorophyll but may be limited for cross-plant functional type studies and comparisons across years.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Forest and Wildlife Ecology, University of Wisconsin-Madison, 1630 Linden Drive, Madison, WI 53706, USA.
- Guangdong Provincial Key Laboratory of Remote Sensing and Geographical Information System, Guangdong Open Laboratory of Geospatial Information Technology and Application, Guangzhou Institute of Geography, Guangdong Acad…
ORCID-Profile: Joelie M Van Beek, Kyle R Kovach, Philip A Townsend
Förderung
- National Science Foundation
- NSF ASCEND Biology Integration Institute (BII)
- NSF Macrosystems Biology and NEON-Enabled Science (MSB-NES)
- USDA McIntire-Stennis Award
Zitieren
APA
Van Beek, J. M., Zheng, T., Wang, Z., Kovach, K. R., & Townsend, P. A. (2024). Evaluation of the Reliability of the CCM-300 Chlorophyll Content Meter in Measuring Chlorophyll Content for Various Plant Functional Types. Sensors. https://doi.org/10.3390/s24154784
Vancouver
Van Beek JM, Zheng T, Wang Z, Kovach KR, Townsend PA. Evaluation of the Reliability of the CCM-300 Chlorophyll Content Meter in Measuring Chlorophyll Content for Various Plant Functional Types. Sensors. 2024. doi:10.3390/s24154784
BibTeX
@article{VanBeek2024,
author = {Van Beek, Joelie M and Zheng, Ting and Wang, Zhihui and Kovach, Kyle R and Townsend, Philip A},
title = {Evaluation of the Reliability of the CCM-300 Chlorophyll Content Meter in Measuring Chlorophyll Content for Various Plant Functional Types},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24154784}
}
EUVIMED