Smartphone IMU Sensors for Human Identification through Hip Joint Angle Analysis
Sensors · 2024
DOI: 10.3390/s24154769 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Rabé Andersson und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering, Mathematics and Science, University of Gävle, 801 76 Gävle, Sweden. Hauptthemen laut MEDLINE: Smartphone, Hip Joint, Gait. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 91 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Gävle and was partially supported by the Ministry of Science and Innovation-Spanish Agency of Research, University of Gävle.
Abstract (Originalsprache)
Gait monitoring using hip joint angles offers a promising approach for person identification, leveraging the capabilities of smartphone inertial measurement units (IMUs). This study investigates the use of smartphone IMUs to extract hip joint angles for distinguishing individuals based on their gait patterns. The data were collected from 10 healthy subjects (8 males, 2 females) walking on a treadmill at 4 km/h for 10 min. A sensor fusion technique that combined accelerometer, gyroscope, and magnetometer data was used to derive meaningful hip joint angles. We employed various machine learning algorithms within the WEKA environment to classify subjects based on their hip joint pattern and achieved a classification accuracy of 88.9%. Our findings demonstrate the feasibility of using hip joint angles for person identification, providing a baseline for future research in gait analysis for biometric applications. This work underscores the potential of smartphone-based gait analysis in personal identification systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrical Engineering, Mathematics and Science, University of Gävle, 801 76 Gävle, Sweden.
- Departamento de Ingeniería Mecánica, Energética y de los Materiales, Escuela de Ingenierías Industriales, Universidad de Extremadura, 06006 Badajoz, Spain.
ORCID-Profile: Rabé Andersson, Javier Bermejo-García, Rafael Agujetas, Mikael Cronhjort
Förderung
- University of Gävle and was partially supported by the Ministry of Science and Innovation-Spanish Agency of Research
- University of Gävle
Zitieren
APA
Andersson, R., Bermejo-García, J., Agujetas, R., Cronhjort, M., & Chilo, J. (2024). Smartphone IMU Sensors for Human Identification through Hip Joint Angle Analysis. Sensors. https://doi.org/10.3390/s24154769
Vancouver
Andersson R, Bermejo-García J, Agujetas R, Cronhjort M, Chilo J. Smartphone IMU Sensors for Human Identification through Hip Joint Angle Analysis. Sensors. 2024. doi:10.3390/s24154769
BibTeX
@article{Andersson2024,
author = {Andersson, Rabé and Bermejo-García, Javier and Agujetas, Rafael and Cronhjort, Mikael and Chilo, José},
title = {Smartphone IMU Sensors for Human Identification through Hip Joint Angle Analysis},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24154769}
}
EUVIMED