Acute Response of Different High-Intensity Interval Training Protocols on Cardiac Auto-Regulation Using Wearable Device
Sensors · 2024
DOI: 10.3390/s24144758 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Myong-Won Seo. Beteiligte Einrichtung: Department of Sport and Leisure Studies, College of Physical Education, Keimyung University, Daegu 42601, Republic of Korea. Hauptthemen laut MEDLINE: High-Intensity Interval Training, Wearable Electronic Devices, Heart Rate. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The purpose of this study was to compare different high-intensity interval training (HIIT) protocols with different lengths of work and rest times for a single session (all three had identical work-to-rest ratios and exercise intensities) for cardiac auto-regulation using a wearable device. With a randomized counter-balanced crossover, 13 physically active young male adults (age: 19.4 years, BMI: 21.9 kg/m2) were included. The HIIT included a warm-up of at least 5 min and three protocols of 10 s/50 s (20 sets), 20 s/100 s (10 sets), and 40 s/200 s (5 sets), with intensities ranging from 115 to 130% Wattmax. Cardiac auto-regulation was measured using a non-invasive method and a wearable device, including HRV and vascular function. Immediately after the HIIT session, the 40 s/200 s protocol produced the most intense stimulation in R-R interval (Δ-33.5%), ln low-frequency domain (Δ-42.6%), ln high-frequency domain (Δ-73.4%), and ln LF/HF ratio (Δ416.7%, all p < 0.05) compared to other protocols of 10 s/50 s and 20 s/100 s. The post-exercise hypotension in the bilateral ankle area was observed in the 40 s/200 s protocol only at 5 min after HIIT (right: Δ-12.2%, left: Δ-12.6%, all p < 0.05). This study confirmed that a longer work time might be more effective in stimulating cardiac auto-regulation using a wearable device, despite identical work-to-rest ratios and exercise intensity. Additional studies with 24 h measurements of cardiac autoregulation using wearable devices in response to various HIIT protocols are warranted.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Sport and Leisure Studies, College of Physical Education, Keimyung University, Daegu 42601, Republic of Korea.
ORCID-Profile: Myong-Won Seo
Zitieren
APA
Seo, M. W. (2024). Acute Response of Different High-Intensity Interval Training Protocols on Cardiac Auto-Regulation Using Wearable Device. Sensors. https://doi.org/10.3390/s24144758
Vancouver
Seo MW. Acute Response of Different High-Intensity Interval Training Protocols on Cardiac Auto-Regulation Using Wearable Device. Sensors. 2024. doi:10.3390/s24144758
BibTeX
@article{Seo2024,
author = {Seo, Myong-Won},
title = {Acute Response of Different High-Intensity Interval Training Protocols on Cardiac Auto-Regulation Using Wearable Device},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24144758}
}