Do Photopletysmographic Parameters of Arterial Stiffness Differ Depending on the Presence of Arterial Hypertension and/or Atherosclerosis?
Sensors · 2024
DOI: 10.3390/s24144572 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Izabela Szołtysek-Bołdys und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of General and Inorganic Chemistry, Faculty of Pharmaceutical Sciences in Sosnowiec, Medical University of Silesia in Katowice, 41-200 Sos…. Hauptthemen laut MEDLINE: Photoplethysmography, Vascular Stiffness, Hypertension, Atherosclerosis. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: "Electrocardiology-Ochojec" Foundation, Medical University of Silesia in Katowice, “Electrocardiology-Ochojec” Foundation.
Abstract (Originalsprache)
Background
Hypertension and atherosclerotic cardiovascular diseases (ASCVD) increase cardiovascular risk and worsen patients’ prognoses. One early predictor of increased risk is a change in arterial stiffness. This study aimed to evaluate arterial stiffness parameters using the non-invasive photoplethysmography (PPG) method in Polish patients with arterial hypertension (AH) and/or atherosclerosis (AS).
Methods
The study group consisted of 333 patients (Caucasians, both sexes, aged 30–85 years old). Patients were analyzed in four groups depending on AH and AS (Group I: patients without AH or AS, Group II: AH patients, Group III: AS patients, and Group IV: AH/AS patients) and, in addition, according to sex and history of SARS-CoV-2 infection. Arterial stiffness parameters, i.e., reflection index (RI), peak-to-peak time (PPT), and stiffness index (SI) were automatically calculated with PPG based on the analysis of the pulse wave contour.
Results
Mean values of RI and SI were higher in men than women (p < 0.001 each). Diastolic blood pressure (DBP) also differed between sexes (p = 0.010). Mean SI values differed between the study groups (p = 0.038) with the highest SI found in AS/AH patients and the lowest—in patients without AH or AS. The mean SI values were significantly lower in women compared to men in both Group I and Group II (p = 0.006 and p < 0.001, respectively). The mean values of RI were also greater in men than in women in Group I and Group II (p < 0.001 for each group). Regarding COVID-19 history, only HR values differed between patients with and without COVID-19 in AH patients (p = 0.012). In AH patients, men had higher values of RI and SI compared to women (p < 0.001 and p < 0.001). On the other hand, AS women with COVID-19 had significantly greater mean values of SI (9.66 m/s ± 1.61) than men with COVID-19 (7.98 m/s ± 1.09) (p = 0.045).
Conclusions
The present study confirmed that sex had a significant impact on arterial stiffness parameters. Both AH and AS affected arterial stiffness. Heart rate was greater in hypertensive patients after COVID-19 compared to hypertensive patients without COVID-19.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of General and Inorganic Chemistry, Faculty of Pharmaceutical Sciences in Sosnowiec, Medical University of Silesia in Katowice, 41-200 Sosnowiec, Poland.
- Department of Electrocardiology and Heart Failure, Medical University of Silesia in Katowice, 40-635 Katowice, Poland.
- Department of Electrocardiology, Upper-Silesian Medical Centre in Katowice, 40-635 Katowice, Poland.
- Department of Basic Biomedical Science, Faculty of Pharmaceutical Sciences in Sosnowiec, Medical University of Silesia in Katowice, 41-200 Sosnowiec, Poland.
ORCID-Profile: Wioleta Zielińska-Danch, Danuta Łoboda, Krzysztof S Gołba, Beata Sarecka-Hujar
Förderung
- "Electrocardiology-Ochojec" Foundation
- Medical University of Silesia in Katowice
- “Electrocardiology-Ochojec” Foundation
Zitieren
APA
Szołtysek-Bołdys, I., Zielińska-Danch, W., Łoboda, D., Gołba, K. S., & Sarecka-Hujar, B. (2024). Do Photopletysmographic Parameters of Arterial Stiffness Differ Depending on the Presence of Arterial Hypertension and/or Atherosclerosis?. Sensors. https://doi.org/10.3390/s24144572
Vancouver
Szołtysek-Bołdys I, Zielińska-Danch W, Łoboda D, Gołba KS, Sarecka-Hujar B. Do Photopletysmographic Parameters of Arterial Stiffness Differ Depending on the Presence of Arterial Hypertension and/or Atherosclerosis?. Sensors. 2024. doi:10.3390/s24144572
BibTeX
@article{SzotysekBodys2024,
author = {Szołtysek-Bołdys, Izabela and Zielińska-Danch, Wioleta and Łoboda, Danuta and Gołba, Krzysztof S and Sarecka-Hujar, Beata},
title = {Do Photopletysmographic Parameters of Arterial Stiffness Differ Depending on the Presence of Arterial Hypertension and/or Atherosclerosis?},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24144572}
}
EUVIMED