Reconstruction of the Chemical Gas Concentration Distribution Using Partial Convolution-Based Image Inpainting
Sensors · 10.07.2024 · 24 (14) · 4470
DOI: 10.3390/s24144470 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 10.07.2024. Verfasst von Minjae Kang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Chem-Bio Technology Center, Agency for Defense Development, Daejeon 34186, Republic of Korea. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Agency for Defense Development.
Abstract (Originalsprache)
An interpolation method, which estimates unknown values with constrained information, is based on mathematical calculations. In this study, we addressed interpolation from an image-based perspective and expanded the use of image inpainting to estimate values at unknown points. When chemical gas is dispersed through a chemical attack or terrorism, it is possible to determine the concentration of the gas at each location by utilizing the deployed sensors. By interpolating the concentrations, we can obtain the contours of gas concentration. Accurately distinguishing the contours of a contaminated region from a map enables the optimal response to minimize damage. However, areas with an insufficient number of sensors have less accurate contours than other areas. In order to achieve more accurate contour data, an image inpainting-based method is proposed to enhance reliability by erasing and reconstructing low-accuracy areas in the contour. Partial convolution is used as the machine learning approach for image-inpainting, with the modified loss function for optimization. In order to train the model, we developed a gas diffusion simulation model and generated a gas concentration contour dataset comprising 100,000 contour images. The results of the model were compared to those of Kriging interpolation, one of the conventional spatial interpolation methods, finally demonstrating 13.21% higher accuracy. This suggests that interpolation from an image-based perspective can achieve higher accuracy than numerical interpolation on well-trained data. The proposed method was validated using gas concentration contour data from the verified gas dispersion modeling software Nuclear Biological Chemical Reporting And Modeling System (NBC_RAMS), which was developed by the Agency for Defense Development, South Korea.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Chem-Bio Technology Center, Agency for Defense Development, Daejeon 34186, Republic of Korea.
ORCID-Profile: Minjae Kang, Jungjae Son, Hyunwoo Nam
Förderung
- Agency for Defense Development
Zitieren
APA
Kang, M., Son, J., Lee, B., & Nam, H. (2024). Reconstruction of the Chemical Gas Concentration Distribution Using Partial Convolution-Based Image Inpainting. Sensors, 24(14), 4470. https://doi.org/10.3390/s24144470
Vancouver
Kang M, Son J, Lee B, Nam H. Reconstruction of the Chemical Gas Concentration Distribution Using Partial Convolution-Based Image Inpainting. Sensors. 2024;24(14):4470. doi:10.3390/s24144470
BibTeX
@article{Kang2024,
author = {Kang, Minjae and Son, Jungjae and Lee, Byungheon and Nam, Hyunwoo},
title = {Reconstruction of the Chemical Gas Concentration Distribution Using Partial Convolution-Based Image Inpainting},
journal = {Sensors},
year = {2024},
volume = {24},
number = {14},
pages = {4470},
doi = {10.3390/s24144470}
}