Acoustic Signal-Based Defect Identification for Directed Energy Deposition-Arc Using Wavelet Time–Frequency Diagrams
Sensors · 07.07.2024 · 24 (13) · 4397
DOI: 10.3390/s24134397 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 07.07.2024. Verfasst von Hui Zhang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Jiangsu Key Laboratory of 3D Printing Equipment & Manufacturing, School of Electrical and Automation Engineering, Nanjing Normal University, Nanjing …. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Key Research and Development Program of Jiangsu Province, the Natural Science Research Project of Jiangsu Higher Education Institutions, Key Research and Development Program of Jiangsu Province.
Abstract (Originalsprache)
Several advantages of directed energy deposition-arc (DED-arc) have garnered considerable research attention including high deposition rates and low costs. However, defects such as discontinuity and pores may occur during the manufacturing process. Defect identification is the key to monitoring and quality assessments of the additive manufacturing process. This study proposes a novel acoustic signal-based defect identification method for DED-arc via wavelet time–frequency diagrams. With the continuous wavelet transform, one-dimensional (1D) acoustic signals acquired in situ during manufacturing are converted into two-dimensional (2D) time–frequency diagrams to train, validate, and test the convolutional neural network (CNN) models. In this study, several CNN models were examined and compared, including AlexNet, ResNet-18, VGG-16, and MobileNetV3. The accuracy of the models was 96.35%, 97.92%, 97.01%, and 98.31%, respectively. The findings demonstrate that the energy distribution of normal and abnormal acoustic signals has significant differences in both the time and frequency domains. The proposed method is verified to identify defects effectively in the manufacturing process and advance the identification time.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Jiangsu Key Laboratory of 3D Printing Equipment & Manufacturing, School of Electrical and Automation Engineering, Nanjing Normal University, Nanjing 210023, China.
ORCID-Profile: Qianru Wu
Förderung
- the Key Research and Development Program of Jiangsu Province
- the Natural Science Research Project of Jiangsu Higher Education Institutions
- Key Research and Development Program of Jiangsu Province
- Natural Science Research Project of Jiangsu Higher Education Institutions
Zitieren
APA
Zhang, H., Wu, Q., Tang, W., & Yang, J. (2024). Acoustic Signal-Based Defect Identification for Directed Energy Deposition-Arc Using Wavelet Time–Frequency Diagrams. Sensors, 24(13), 4397. https://doi.org/10.3390/s24134397
Vancouver
Zhang H, Wu Q, Tang W, Yang J. Acoustic Signal-Based Defect Identification for Directed Energy Deposition-Arc Using Wavelet Time–Frequency Diagrams. Sensors. 2024;24(13):4397. doi:10.3390/s24134397
BibTeX
@article{Zhang2024,
author = {Zhang, Hui and Wu, Qianru and Tang, Wenlai and Yang, Jiquan},
title = {Acoustic Signal-Based Defect Identification for Directed Energy Deposition-Arc Using Wavelet Time–Frequency Diagrams},
journal = {Sensors},
year = {2024},
volume = {24},
number = {13},
pages = {4397},
doi = {10.3390/s24134397}
}