A Retinal Vessel Segmentation Method Based on the Sharpness-Aware Minimization Model
Sensors · 2024
DOI: 10.3390/s24134267 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Iqra Mariam und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Electronics and Information Engineering, Liaoning University of Technology, Jinzhou 121001, China. Hauptthemen laut MEDLINE: Retinal Vessels, Algorithms. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Key project (LJKZ0618) of scientific research of the Education Department of Liaoning Province, China, Science and Technology Plan Project, Scientific Research of the Education Department of Liaoning Province, China.
Abstract (Originalsprache)
Retinal vessel segmentation is crucial for diagnosing and monitoring various eye diseases such as diabetic retinopathy, glaucoma, and hypertension. In this study, we examine how sharpness-aware minimization (SAM) can improve RF-UNet’s generalization performance. RF-UNet is a novel model for retinal vessel segmentation. We focused our experiments on the digital retinal images for vessel extraction (DRIVE) dataset, which is a benchmark for retinal vessel segmentation, and our test results show that adding SAM to the training procedure leads to notable improvements. Compared to the non-SAM model (training loss of 0.45709 and validation loss of 0.40266), the SAM-trained RF-UNet model achieved a significant reduction in both training loss (0.094225) and validation loss (0.08053). Furthermore, compared to the non-SAM model (training accuracy of 0.90169 and validation accuracy of 0.93999), the SAM-trained model demonstrated higher training accuracy (0.96225) and validation accuracy (0.96821). Additionally, the model performed better in terms of sensitivity, specificity, AUC, and F1 score, indicating improved generalization to unseen data. Our results corroborate the notion that SAM facilitates the learning of flatter minima, thereby improving generalization, and are consistent with other research highlighting the advantages of advanced optimization methods. With wider implications for other medical imaging tasks, these results imply that SAM can successfully reduce overfitting and enhance the robustness of retinal vessel segmentation models. Prospective research avenues encompass verifying the model on vaster and more diverse datasets and investigating its practical implementation in real-world clinical situations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Electronics and Information Engineering, Liaoning University of Technology, Jinzhou 121001, China.
ORCID-Profile: Iqra Mariam, Kaleb Gadson
Förderung
- Key project (LJKZ0618) of scientific research of the Education Department of Liaoning Province, China
- Science and Technology Plan Project
- Scientific Research of the Education Department of Liaoning Province, China
Zitieren
APA
Mariam, I., Xue, X., & Gadson, K. (2024). A Retinal Vessel Segmentation Method Based on the Sharpness-Aware Minimization Model. Sensors. https://doi.org/10.3390/s24134267
Vancouver
Mariam I, Xue X, Gadson K. A Retinal Vessel Segmentation Method Based on the Sharpness-Aware Minimization Model. Sensors. 2024. doi:10.3390/s24134267
BibTeX
@article{Mariam2024,
author = {Mariam, Iqra and Xue, Xiaorong and Gadson, Kaleb},
title = {A Retinal Vessel Segmentation Method Based on the Sharpness-Aware Minimization Model},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24134267}
}
EUVIMED