EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Normal-Incidence Germanium Photodetectors Integrated with Polymer Microlenses for Optical Fiber Communication Applications

Yu-Hsuan Liu iD, Chia-Peng Lin, Po-Wei Chen, Chia-Tai Tsao, Chun-Chi Lin, Tsung-Ting Wu, Likarn Wang, Neil Na iD

Sensors · 29.06.2024 · 24 (13) · 4221

DOI: 10.3390/s24134221 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 29.06.2024. Verfasst von Yu-Hsuan Liu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Photonics Technologies, National Tsing Hua University, Hsinchu 30013, Taiwan. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We present a novel photon-acid diffusion method to integrate polymer microlenses (MLs) on a four-channel, high-speed photo-receiver consisting of normal-incidence germanium (Ge) p-i-n photodiodes (PDs) fabricated on a 200 mm Si substrate. For a 29 µm diameter PD capped with a 54 µm diameter ML, its dark current, responsivity, 3 dB bandwidth (BW), and effective aperture size at −3 V bias and 850 nm wavelength are measured to be 138 nA, 0.6 A/W, 21.4 GHz, and 54 µm, respectively. The enlarged aperture size significantly decouples the tradeoff between aperture size and BW and enhances the optical fiber misalignment tolerance from ±5 µm to ±15 µm to ease the module packaging precision. The sensitivity of the photo-receiver is measured to be −9.2 dBm at 25.78 Gb/s with a bit error rate of 10−12 using non-return-to-zero (NRZ) transmission. Reliability tests are performed, and the results show that the fabricated Ge PDs integrated with polymer MLs pass the GR-468 reliability assurance standard. The demonstrated photo-receiver, a first of its kind to the best of our knowledge, features decent performance, high yield, high throughput, low cost, and compatibility with complementary metal-oxide-semiconductor (CMOS) fabrication processes, and may be further applied to 400 Gb/s pulse-amplitude modulation four-level (PAM4) communication.

Schlagwörter

Stichwörter der Autor:innen

germanium photodiodehigh speedoptical communicationphoton-acid diffusionpolymer microlensreliability test

Autor:innen und Institutionen

  • Institute of Photonics Technologies, National Tsing Hua University, Hsinchu 30013, Taiwan.
  • Artilux Inc., Hsinchu 30288, Taiwan.

ORCID-Profile: Yu-Hsuan Liu, Neil Na

Zitieren

APA

Liu, Y. H., Lin, C. P., Chen, P. W., Tsao, C. T., Lin, C. C., Wu, T. T., Wang, L., & Na, N. (2024). Normal-Incidence Germanium Photodetectors Integrated with Polymer Microlenses for Optical Fiber Communication Applications. Sensors, 24(13), 4221. https://doi.org/10.3390/s24134221

Vancouver

Liu YH, Lin CP, Chen PW, Tsao CT, Lin CC, Wu TT, et al. Normal-Incidence Germanium Photodetectors Integrated with Polymer Microlenses for Optical Fiber Communication Applications. Sensors. 2024;24(13):4221. doi:10.3390/s24134221

BibTeX
@article{Liu2024,
  author = {Liu, Yu-Hsuan and Lin, Chia-Peng and Chen, Po-Wei and Tsao, Chia-Tai and Lin, Chun-Chi and Wu, Tsung-Ting and Wang, Likarn and Na, Neil},
  title = {Normal-Incidence Germanium Photodetectors Integrated with Polymer Microlenses for Optical Fiber Communication Applications},
  journal = {Sensors},
  year = {2024},
  volume = {24},
  number = {13},
  pages = {4221},
  doi = {10.3390/s24134221}
}