EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Cell–Electrode Models for Impedance Analysis of Epithelial and Endothelial Monolayers Cultured on Microelectrodes

Wei-Chih Chiu, Wei-Ling Chen, Yi-Ting Lai, Yu-Han Hung iD, Chun-Min Lo iD

Sensors · 2024

DOI: 10.3390/s24134214 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Wei-Chih Chiu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei 11221, Taiwan. Hauptthemen laut MEDLINE: Electric Impedance, Microelectrodes, Epithelial Cells, Endothelial Cells. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science and Technology of the Republic of China, Taiwan, Ministry of Science and Technology of the Republic of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electric cell–substrate impedance sensing has been used to measure transepithelial and transendothelial impedances of cultured cell layers and extract cell parameters such as junctional resistance, cell–substrate separation, and membrane capacitance. Previously, a three-path cell–electrode model comprising two transcellular pathways and one paracellular pathway was developed for the impedance analysis of MDCK cells. By ignoring the resistances of the lateral intercellular spaces, we develop a simplified three-path model for the impedance analysis of epithelial cells and solve the model equations in a closed form. The calculated impedance values obtained from this simplified cell–electrode model at frequencies ranging from 31.25 Hz to 100 kHz agree well with the experimental data obtained from MDCK and OVCA429 cells. We also describe how the change in each model-fitting parameter influences the electrical impedance spectra of MDCK cell layers. By assuming that the junctional resistance is much smaller than the specific impedance through the lateral cell membrane, the simplified three-path model reduces to a two-path model, which can be used for the impedance analysis of endothelial cells and other disk-shaped cells with low junctional resistances. The measured impedance spectra of HUVEC and HaCaT cell monolayers nearly coincide with the impedance data calculated from the two-path model.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electric ImpedanceMicroelectrodesEpithelial CellsEndothelial CellsDogsAnimalsHumansMadin Darby Canine Kidney CellsHuman Umbilical Vein Endothelial CellsCell LineModels, Biological

Stichwörter der Autor:innen

cell–electrode modelelectric cell–substrate impedance sensing (ECIS)endothelial cellsepithelial cellsimpedance analysis

Autor:innen und Institutionen

  • Department of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei 11221, Taiwan.
  • Research Center for Applied Sciences, Academia Sinica, Taipei 11529, Taiwan.
  • Department of Neurology, University of California, Irvine, CA 92697, USA.

ORCID-Profile: Yu-Han Hung, Chun-Min Lo

Förderung

  • Ministry of Science and Technology of the Republic of China, Taiwan
  • Ministry of Science and Technology of the Republic of China

Zitieren

APA

Chiu, W. C., Chen, W. L., Lai, Y. T., Hung, Y. H., & Lo, C. M. (2024). Cell–Electrode Models for Impedance Analysis of Epithelial and Endothelial Monolayers Cultured on Microelectrodes. Sensors. https://doi.org/10.3390/s24134214

Vancouver

Chiu WC, Chen WL, Lai YT, Hung YH, Lo CM. Cell–Electrode Models for Impedance Analysis of Epithelial and Endothelial Monolayers Cultured on Microelectrodes. Sensors. 2024. doi:10.3390/s24134214

BibTeX
@article{Chiu2024,
  author = {Chiu, Wei-Chih and Chen, Wei-Ling and Lai, Yi-Ting and Hung, Yu-Han and Lo, Chun-Min},
  title = {Cell–Electrode Models for Impedance Analysis of Epithelial and Endothelial Monolayers Cultured on Microelectrodes},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24134214}
}
Kostenlos starten →