Optimal Time Frequency Fusion Symmetric Dot Pattern Bearing Fault Feature Enhancement and Diagnosis
Sensors · 27.06.2024 · 24 (13) · 4186
DOI: 10.3390/s24134186 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 27.06.2024. Verfasst von Guanlong Liang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Naval Architecture and Shipping College, Guangdong Ocean University, Zhanjiang 524088, China. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, the Program for Scientific Research Start-Up Funds of Guangdong Ocean University, Zhanjiang Non-funded Science and Technology Tesearch Project.
Abstract (Originalsprache)
Regarding the difficulty of extracting the acquired fault signal features of bearings from a strong background noise vibration signal, coupled with the fact that one-dimensional (1D) signals provide limited fault information, an optimal time frequency fusion symmetric dot pattern (SDP) bearing fault feature enhancement and diagnosis method is proposed. Firstly, the vibration signals are transformed into two-dimensional (2D) features by the time frequency fusion algorithm SDP, which can multi-scale analyze the fluctuations of signals at minor scales, as well as enhance bearing fault features. Secondly, the bat algorithm is employed to optimize the SDP parameters adaptively. It can effectively improve the distinctions between various types of faults. Finally, the fault diagnosis model can be constructed by a deep convolutional neural network (DCNN). To validate the effectiveness of the proposed method, Case Western Reserve University’s (CWRU) bearing fault dataset and bearing fault dataset laboratory experimental platform were used. The experimental results illustrate that the fault diagnosis accuracy of the proposed method is 100%, which proves the feasibility and effectiveness of the proposed method. By comparing with other 2D transformer methods, the experimental results illustrate that the proposed method achieves the highest accuracy in bearing fault diagnosis. It validated the superiority of the proposed methodology.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Naval Architecture and Shipping College, Guangdong Ocean University, Zhanjiang 524088, China.
- Technical Research Center for Ship Intelligence and Safety Engineering of Guangdong Province, Zhanjiang 524088, China.
- Guangdong Provincial Key Laboratory of Intelligent Equipment for South China Sea Marine Ranching, Zhanjiang 524088, China.
ORCID-Profile: Zhiqiang Liao, Baozhu Jia
Förderung
- National Natural Science Foundation of China
- the Program for Scientific Research Start-Up Funds of Guangdong Ocean University
- Zhanjiang Non-funded Science and Technology Tesearch Project
- Zhanjiang Non-funded Science and Technology Research Project
Zitieren
APA
Liang, G., Song, X., Liao, Z., & Jia, B. (2024). Optimal Time Frequency Fusion Symmetric Dot Pattern Bearing Fault Feature Enhancement and Diagnosis. Sensors, 24(13), 4186. https://doi.org/10.3390/s24134186
Vancouver
Liang G, Song X, Liao Z, Jia B. Optimal Time Frequency Fusion Symmetric Dot Pattern Bearing Fault Feature Enhancement and Diagnosis. Sensors. 2024;24(13):4186. doi:10.3390/s24134186
BibTeX
@article{Liang2024,
author = {Liang, Guanlong and Song, Xuewei and Liao, Zhiqiang and Jia, Baozhu},
title = {Optimal Time Frequency Fusion Symmetric Dot Pattern Bearing Fault Feature Enhancement and Diagnosis},
journal = {Sensors},
year = {2024},
volume = {24},
number = {13},
pages = {4186},
doi = {10.3390/s24134186}
}