Development and Integration of a Digital Twin Model for a Real Hydroelectric Power Plant
Sensors · 27.06.2024 · 24 (13) · 4174
DOI: 10.3390/s24134174 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 27.06.2024. Verfasst von Mustafa Ersan und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Electronics Engineering, Graduate School of Natural and Applied Sciences, Gazi University, Ankara 06560, Türkiye. Die Arbeit wurde bisher 40-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
In this study, a digital twin model of a hydroelectric power plant has been created. Models of the entire power plant have been created and malfunction situations of a sensor located after the inlet valve of the plant have been analyzed using a programmable logic controller (PLC). As a feature of the digital twin (DT), the error prediction and prevention function has been studied specifically for the pressure sensor. The accuracy and reliability of the data obtained from the sensor are compared with the data obtained from the DT model. The comparison results are evaluated and erroneous data are identified. In this way, it is determined whether the malfunction occurring in the system is a real malfunction or a malfunction caused by measurement or connection errors. In the case of sensor failure or measurement-related malfunction, this situation is determined through the digital twin-based control mechanism. In the case of actual failure, the system is stopped, but in the case of measurement or connection errors, since the data are calculated by the DT model, the value in the specified region is known and thus there is no need to stop the system. This prevents production loss in the hydroelectric power plant by ensuring the continuity of the system in case of errors.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrical and Electronics Engineering, Graduate School of Natural and Applied Sciences, Gazi University, Ankara 06560, Türkiye.
- Department of Electrical and Electronics Engineering, Faculty of Technology, Gazi University, Ankara 06560, Türkiye.
ORCID-Profile: Mustafa Ersan, Erdal Irmak
Zitieren
APA
Ersan, M., & Irmak, E. (2024). Development and Integration of a Digital Twin Model for a Real Hydroelectric Power Plant. Sensors, 24(13), 4174. https://doi.org/10.3390/s24134174
Vancouver
Ersan M, Irmak E. Development and Integration of a Digital Twin Model for a Real Hydroelectric Power Plant. Sensors. 2024;24(13):4174. doi:10.3390/s24134174
BibTeX
@article{Ersan2024,
author = {Ersan, Mustafa and Irmak, Erdal},
title = {Development and Integration of a Digital Twin Model for a Real Hydroelectric Power Plant},
journal = {Sensors},
year = {2024},
volume = {24},
number = {13},
pages = {4174},
doi = {10.3390/s24134174}
}
EUVIMED