Comparing the Drop Vertical Jump Tracking Performance of the Azure Kinect to the Kinect V2
Sensors · 2024
DOI: 10.3390/s24123814 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Sensors, 2024. Verfasst von Patrik Abdelnour und 6 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine and Health Sciences, McGill University, 3605 Rue de la Montagne, Montreal, QC H3G 2M1, Canada. Hauptthemen laut MEDLINE: Anterior Cruciate Ligament Injuries. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: I+P Partnership Grants.
Abstract (Originalsprache)
Traditional motion analysis systems are impractical for widespread screening of non-contact anterior cruciate ligament (ACL) injury risk. The Kinect V2 has been identified as a portable and reliable alternative but was replaced by the Azure Kinect. We hypothesize that the Azure Kinect will assess drop vertical jump (DVJ) parameters associated with ACL injury risk with similar accuracy to its predecessor, the Kinect V2. Sixty-nine participants performed DVJs while being recorded by both the Azure Kinect and the Kinect V2 simultaneously. Our software analyzed the data to identify initial coronal, peak coronal, and peak sagittal knee angles. Agreement between the two systems was evaluated using the intraclass correlation coefficient (ICC). There was poor agreement between the Azure Kinect and the Kinect V2 for initial and peak coronal angles (ICC values ranging from 0.135 to 0.446), and moderate agreement for peak sagittal angles (ICC = 0.608, 0.655 for left and right knees, respectively). At this point in time, the Azure Kinect system is not a reliable successor to the Kinect V2 system for assessment of initial coronal, peak coronal, and peak sagittal angles during a DVJ, despite demonstrating superior tracking of continuous knee angles. Alternative motion analysis systems should be explored.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Medicine and Health Sciences, McGill University, 3605 Rue de la Montagne, Montreal, QC H3G 2M1, Canada.
- Division of Orthopaedic Surgery, McGill University Health Centre, 1650 Cedar Ave, Montreal, QC H3G 1A4, Canada.
- Department of Experimental Surgery, McGill University, 845 Sherbrooke St W, Montreal, QC H3A 0G4, Canada.
- Department of Computer Science and Software Engineering, Concordia University, 1455 De Maisonneuve Blvd. W., Montreal, QC H3G 1M8, Canada.
ORCID-Profile: Patrik Abdelnour, Kevin Y Zhao, Athanasios Babouras, Nicolaos Karatzas, Thomas Fevens
Förderung
- I+P Partnership Grants
Zitieren
APA
Abdelnour, P., Zhao, K. Y., Babouras, A., Corban, J. P. A. H., Karatzas, N., Fevens, T., & Martineau, P. A. (2024). Comparing the Drop Vertical Jump Tracking Performance of the Azure Kinect to the Kinect V2. Sensors. https://doi.org/10.3390/s24123814
Vancouver
Abdelnour P, Zhao KY, Babouras A, Corban JPAH, Karatzas N, Fevens T, et al. Comparing the Drop Vertical Jump Tracking Performance of the Azure Kinect to the Kinect V2. Sensors. 2024. doi:10.3390/s24123814
BibTeX
@article{Abdelnour2024,
author = {Abdelnour, Patrik and Zhao, Kevin Y and Babouras, Athanasios and Corban, Jason Philip Aaron Hiro and Karatzas, Nicolaos and Fevens, Thomas and Martineau, Paul Andre},
title = {Comparing the Drop Vertical Jump Tracking Performance of the Azure Kinect to the Kinect V2},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24123814}
}
EUVIMED