Utilizing COVID-19 as a Model for Diagnostics Using an Electrochemical Sensor
Sensors · 2024
DOI: 10.3390/s24123772 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Ava Gevaerd und 15 weiteren Autor:innen. Beteiligte Einrichtung: Research and Development Department, Hilab Campus, Rua José A. Possebom, 800, Curitiba, Parana 81270-185, Brazil. Hauptthemen laut MEDLINE: COVID-19, Biosensing Techniques, SARS-CoV-2, Dielectric Spectroscopy. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hi Technologies.
Abstract (Originalsprache)
This paper reports a rapid and sensitive sensor for the detection and quantification of the COVID-19 N-protein (N-PROT) via an electrochemical mechanism. Single-frequency electrochemical impedance spectroscopy was used as a transduction method for real-time measurement of the N-PROT in an immunosensor system based on gold-conjugate-modified carbon screen-printed electrodes (Cov-Ag-SPE). The system presents high selectivity attained through an optimal stimulation signal composed of a 0.0 V DC potential and 10 mV RMS−1 AC signal at 100 Hz over 300 s. The Cov-Ag-SPE showed a log response toward N-PROT detection at concentrations from 1.0 ng mL−1 to 10.0 μg mL−1, with a 0.977 correlation coefficient for the phase (θ) variation. An ML-based approach could be created using some aspects observed from the positive and negative samples; hence, it was possible to classify 252 samples, reaching 83.0, 96.2 and 91.3% sensitivity, specificity, and accuracy, respectively, with confidence intervals (CI) ranging from 73.0 to 100.0%. Because impedance spectroscopy measurements can be performed with low-cost portable instruments, the immunosensor proposed here can be applied in point-of-care diagnostics for mass testing, even in places with limited resources, as an alternative to the common diagnostics methods.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Research and Development Department, Hilab Campus, Rua José A. Possebom, 800, Curitiba, Parana 81270-185, Brazil.
- School of Medicine-Campus PUCPR, Rua Imaculada Conceição, 1155, Prado Velho, Curitiba, Parana 80215-901, Brazil.
ORCID-Profile: Ava Gevaerd, Jeferson L Gogola, Diego R P Nicollete, Erika B Santiago, Halanna P Riedi, Bernardo M M de Almeida
Förderung
- Hi Technologies
Zitieren
APA
Gevaerd, A., Carneiro, E. A., Gogola, J. L., Nicollete, D. R. P., Santiago, E. B., Riedi, H. P., Timm, A., Predebon, J. V., Hartmann, L. F., Ribeiro, V. H. A., Rochitti, C., Marques, G. L., Loesch, M. M. O. N., Almeida, B. M. M., Rogal-Junior, S., & Figueredo, M. V. M. (2024). Utilizing COVID-19 as a Model for Diagnostics Using an Electrochemical Sensor. Sensors. https://doi.org/10.3390/s24123772
Vancouver
Gevaerd A, Carneiro EA, Gogola JL, Nicollete DRP, Santiago EB, Riedi HP, et al. Utilizing COVID-19 as a Model for Diagnostics Using an Electrochemical Sensor. Sensors. 2024. doi:10.3390/s24123772
BibTeX
@article{Gevaerd2024,
author = {Gevaerd, Ava and Carneiro, Emmanuelle A and Gogola, Jeferson L and Nicollete, Diego R P and Santiago, Erika B and Riedi, Halanna P and Timm, Adriano and Predebon, João V and Hartmann, Luis F and Ribeiro, Victor H A and Rochitti, Carlos and Marques, Gustavo L and Loesch, Maira M O N and Almeida, Bernardo M M de and Rogal-Junior, Sérgio and Figueredo, Marcus V M},
title = {Utilizing COVID-19 as a Model for Diagnostics Using an Electrochemical Sensor},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24123772}
}
EUVIMED