Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von David Hollinger und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Auburn University, Auburn, AL 36849, USA. Hauptthemen laut MEDLINE: Movement, Machine Learning, Algorithms. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: United States Army Combat Capabilities Development Command, United States Army Combat Capabilities and Development Command.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The use of wearable sensors, such as inertial measurement units (IMUs), and machine learning for human intent recognition in health-related areas has grown considerably. However, there is limited research exploring how IMU quantity and placement affect human movement intent prediction (HMIP) at the joint level. The objective of this study was to analyze various combinations of IMU input signals to maximize the machine learning prediction accuracy for multiple simple movements. We trained a Random Forest algorithm to predict future joint angles across these movements using various sensor features. We hypothesized that joint angle prediction accuracy would increase with the addition of IMUs attached to adjacent body segments and that non-adjacent IMUs would not increase the prediction accuracy. The results indicated that the addition of adjacent IMUs to current joint angle inputs did not significantly increase the prediction accuracy (RMSE of 1.92° vs. 3.32° at the ankle, 8.78° vs. 12.54° at the knee, and 5.48° vs. 9.67° at the hip). Additionally, including non-adjacent IMUs did not increase the prediction accuracy (RMSE of 5.35° vs. 5.55° at the ankle, 20.29° vs. 20.71° at the knee, and 14.86° vs. 13.55° at the hip). These results demonstrated how future joint angle prediction during simple movements did not improve with the addition of IMUs alongside current joint angle inputs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MovementMachine LearningAlgorithmsHumansMaleAdultFemaleWearable Electronic DevicesYoung AdultRange of Motion, ArticularBiomechanical PhenomenaKnee JointJointsAnkle JointHip Joint

Stichwörter der Autor:innen

accelerometersgyroscopesmovement intent predictionwearable sensors

Autor:innen und Institutionen

  • Department of Mechanical Engineering, Auburn University, Auburn, AL 36849, USA.
  • Department of Industrial & Systems Engineering, Auburn University, Auburn, AL 36849, USA.
  • Department of Industrial & Systems Engineering and Engineering Management, University of Alabama-Huntsville, Huntsville, AL 35899, USA.

ORCID-Profile: David Hollinger, Mark C Schall

Förderung

  • United States Army Combat Capabilities Development Command
  • United States Army Combat Capabilities and Development Command

Zitieren

APA

Hollinger, D., Schall, M. C., Chen, H., & Zabala, M. (2024). The Effect of Sensor Feature Inputs on Joint Angle Prediction across Simple Movements. Sensors. https://doi.org/10.3390/s24113657

Vancouver

Hollinger D, Schall MC, Chen H, Zabala M. The Effect of Sensor Feature Inputs on Joint Angle Prediction across Simple Movements. Sensors. 2024. doi:10.3390/s24113657

BibTeX
@article{Hollinger2024,
  author = {Hollinger, David and Schall, Mark C and Chen, Howard and Zabala, Michael},
  title = {The Effect of Sensor Feature Inputs on Joint Angle Prediction across Simple Movements},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24113657}
}
Kostenlos starten →