Visual and Quantitative Evaluation of Low-Concentration Bismuth in Dual-Contrast Imaging of Iodine and Bismuth Using Clinical Photon-Counting CT
Sensors · 2024
DOI: 10.3390/s24113567 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Afrouz Ataei und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, UT Southwestern Medical Center, Dallas, TX 75390, USA. Hauptthemen laut MEDLINE: Bismuth, Iodine, Phantoms, Imaging, Tomography, X-Ray Computed. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: RSNA Research & Education Foundation.
Abstract (Originalsprache)
Simultaneous dual-contrast imaging of iodine and bismuth has shown promise in prior phantom and animal studies utilizing spectral CT. However, it is noted that in previous studies, Pepto-Bismol has frequently been employed as the source of bismuth, exceeding the recommended levels for human subjects. This investigation sought to assess the feasibility of visually differentiating and precisely quantifying low-concentration bismuth using clinical dual-source photon-counting CT (PCCT) in a scenario involving both iodinated and bismuth-based contrast materials. Four bismuth samples (0.6, 1.3, 2.5, and 5.1 mg/mL) were prepared using Pepto-Bismol, alongside three iodine rods (1, 2, and 5 mg/mL), inserted into multi-energy CT phantoms with three different sizes, and scanned on a PCCT system at three tube potentials (120, 140, and Sn140 kV). A generic image-based three-material decomposition method generated iodine and bismuth maps, with mean mass concentrations and noise levels measured. The root-mean-square errors for iodine and bismuth determined the optimal tube potential. The tube potential of 140 kV demonstrated optimal quantification performance when both iodine and bismuth were considered. Distinct differentiation of iodine rods with all three concentrations and bismuth samples with mass concentrations ≥ 1.3 mg/mL was observed across all phantom sizes at the optimal kV setting.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX 75390, USA.
- Department of Radiology, Mayo Clinic, Rochester, MN 55905, USA.
- Siemens Medical Solutions USA Inc., Malvern, PA 19355, USA.
ORCID-Profile: Todd C Soesbe, Kristina A Hallam, Liqiang Ren
Förderung
- RSNA Research & Education Foundation
Zitieren
APA
Ataei, A., Vasan, V., Soesbe, T. C., Brewington, C. C., Zhou, Z., Yu, L., Hallam, K. A., & Ren, L. (2024). Visual and Quantitative Evaluation of Low-Concentration Bismuth in Dual-Contrast Imaging of Iodine and Bismuth Using Clinical Photon-Counting CT. Sensors. https://doi.org/10.3390/s24113567
Vancouver
Ataei A, Vasan V, Soesbe TC, Brewington CC, Zhou Z, Yu L, et al. Visual and Quantitative Evaluation of Low-Concentration Bismuth in Dual-Contrast Imaging of Iodine and Bismuth Using Clinical Photon-Counting CT. Sensors. 2024. doi:10.3390/s24113567
BibTeX
@article{Ataei2024,
author = {Ataei, Afrouz and Vasan, Vasantha and Soesbe, Todd C and Brewington, Cecelia C and Zhou, Zhongxing and Yu, Lifeng and Hallam, Kristina A and Ren, Liqiang},
title = {Visual and Quantitative Evaluation of Low-Concentration Bismuth in Dual-Contrast Imaging of Iodine and Bismuth Using Clinical Photon-Counting CT},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24113567}
}
EUVIMED