EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access · CC BY 4.0

Implantable Pressure-Sensing Devices for Monitoring Abdominal Aortic Aneurysms in Post-Endovascular Aneurysm Repair

Nuno P Silva iD, Bilal Amin iD, Eoghan Dunne iD, Niamh Hynes iD, Martin O'Halloran iD, Adnan Elahi iD

Sensors · 2024

DOI: 10.3390/s24113526 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Sensors, 2024. Verfasst von Nuno P Silva und 5 weiteren Autor:innen. Beteiligte Einrichtung: Translational Medical Device Lab, University of Galway, H91 TK33 Galway, Ireland. Hauptthemen laut MEDLINE: Aortic Aneurysm, Abdominal, Endovascular Procedures. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 91 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science Foundation Ireland.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Over the past two decades, there has been extensive research into surveillance methods for the post-endovascular repair of abdominal aortic aneurysms, highlighting the importance of these technologies in supplementing or even replacing conventional image-screening modalities. This review aims to provide an overview of the current status of alternative surveillance solutions for endovascular aneurysm repair, while also identifying potential aneurysm features that could be used to develop novel monitoring technologies. It offers a comprehensive review of these recent clinical advances, comparing new and standard clinical practices. After introducing the clinical understanding of abdominal aortic aneurysms and exploring current treatment procedures, the paper discusses the current surveillance methods for endovascular repair, contrasting them with recent pressure-sensing technologies. The literature on three commercial pressure-sensing devices for post-endovascular repair surveillance is analyzed. Various pre-clinical and clinical studies assessing the safety and efficacy of these devices are reviewed, providing a comparative summary of their outcomes. The review of the results from pre-clinical and clinical studies suggests a consistent trend of decreased blood pressure in the excluded aneurysm sac post-repair. However, despite successful pressure readings from the aneurysm sac, no strong link has been established to translate these measurements into the presence or absence of endoleaks. Furthermore, the results do not allow for a conclusive determination of ongoing aneurysm sac growth. Consequently, a strong clinical need persists for monitoring endoleaks and aneurysm growth following endovascular repair.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic Aneurysm, AbdominalEndovascular ProceduresHumansMonitoring, PhysiologicBlood PressurePressureProstheses and ImplantsEndovascular Aneurysm Repair

Stichwörter der Autor:innen

abdominal aortic aneurysmendovascular aneurysm repairimplantable pressure sensorpost-EVAR surveillance

Autor:innen und Institutionen

  • Translational Medical Device Lab, University of Galway, H91 TK33 Galway, Ireland.
  • Electrical and Electronic Engineering, University of Galway, H91 TK33 Galway, Ireland.
  • School of Medicine, University of Galway, H91 TK33 Galway, Ireland.
  • Western Vascular Institute, Galway Clinic, Doughiska Road, H91 HHT0 Galway, Ireland.

ORCID-Profile: Nuno P Silva, Bilal Amin, Eoghan Dunne, Niamh Hynes, Martin O'Halloran, Adnan Elahi

Förderung

  • Science Foundation Ireland

Zitieren

APA

Silva, N. P., Amin, B., Dunne, E., Hynes, N., O'Halloran, M., & Elahi, A. (2024). Implantable Pressure-Sensing Devices for Monitoring Abdominal Aortic Aneurysms in Post-Endovascular Aneurysm Repair. Sensors. https://doi.org/10.3390/s24113526

Vancouver

Silva NP, Amin B, Dunne E, Hynes N, O'Halloran M, Elahi A. Implantable Pressure-Sensing Devices for Monitoring Abdominal Aortic Aneurysms in Post-Endovascular Aneurysm Repair. Sensors. 2024. doi:10.3390/s24113526

BibTeX
@article{Silva2024,
  author = {Silva, Nuno P and Amin, Bilal and Dunne, Eoghan and Hynes, Niamh and O'Halloran, Martin and Elahi, Adnan},
  title = {Implantable Pressure-Sensing Devices for Monitoring Abdominal Aortic Aneurysms in Post-Endovascular Aneurysm Repair},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24113526}
}
Kostenlos starten →