The Agreement between Wearable Sensors and Force Plates for the Analysis of Stride Time Variability
Sensors · 2024
DOI: 10.3390/s24113378 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Patrick Slattery und 5 weiteren Autor:innen. Beteiligte Einrichtung: Sport, Performance and Nutrition Research Group, School of Allied Health, Human Services and Sport, La Trobe University, Melbourne, VIC 3083, Austral…. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Military Personnel. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: La Trobe University, Australian Government Research Training Program (RTP) scholarship.
Abstract (Originalsprache)
The variability and regularity of stride time may help identify individuals at a greater risk of injury during military load carriage. Wearable sensors could provide a cost-effective, portable solution for recording these measures, but establishing their validity is necessary. This study aimed to determine the agreement of several measures of stride time variability across five wearable sensors (Opal APDM, Vicon Blue Trident, Axivity, Plantiga, Xsens DOT) and force plates during military load carriage. Nineteen Australian Army trainee soldiers (age: 24.8 ± 5.3 years, height: 1.77 ± 0.09 m, body mass: 79.5 ± 15.2 kg, service: 1.7 ± 1.7 years) completed three 12-min walking trials on an instrumented treadmill at 5.5 km/h, carrying 23 kg of an external load. Simultaneously, 512 stride time intervals were identified from treadmill-embedded force plates and each sensor where linear (standard deviation and coefficient of variation) and non-linear (detrended fluctuation analysis and sample entropy) measures were obtained. Sensor and force plate agreement was evaluated using Pearson’s r and intraclass correlation coefficients. All sensors had at least moderate agreement (ICC > 0.5) and a strong positive correlation (r > 0.5). These results suggest wearable devices could be employed to quantify linear and non-linear measures of stride time variability during military load carriage.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Sport, Performance and Nutrition Research Group, School of Allied Health, Human Services and Sport, La Trobe University, Melbourne, VIC 3083, Australia.
- Department of Nursing and Allied Health, School of Health Sciences, Swinburne University of Technology, Hawthorn, VIC 3122, Australia.
- Department of Medicine, The University of Melbourne, Parkville, VIC 3050, Australia.
- Academy of Sport and Physical Activity, Sheffield Hallam University, Sheffield S10 2DN, UK.
- School of Science and Technology, Nottingham Trent University, Nottingham NG11 8NS, UK.
- Applied Sport Science and Exercise Testing Laboratory, School of Life and Environmental Sciences, University of Newcastle, Ourimbah, NSW 2258, Australia.
ORCID-Profile: Patrick Slattery, L Eduardo Cofré Lizama, Paul Gastin, Ben Dascombe, Kane Middleton
Förderung
- La Trobe University
- Australian Government Research Training Program (RTP) scholarship
Zitieren
APA
Slattery, P., Cofré Lizama, L. E., Wheat, J., Gastin, P., Dascombe, B., & Middleton, K. (2024). The Agreement between Wearable Sensors and Force Plates for the Analysis of Stride Time Variability. Sensors. https://doi.org/10.3390/s24113378
Vancouver
Slattery P, Cofré Lizama LE, Wheat J, Gastin P, Dascombe B, Middleton K. The Agreement between Wearable Sensors and Force Plates for the Analysis of Stride Time Variability. Sensors. 2024. doi:10.3390/s24113378
BibTeX
@article{Slattery2024,
author = {Slattery, Patrick and Cofré Lizama, L Eduardo and Wheat, Jon and Gastin, Paul and Dascombe, Ben and Middleton, Kane},
title = {The Agreement between Wearable Sensors and Force Plates for the Analysis of Stride Time Variability},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24113378}
}
EUVIMED